Installation Instructions

POINT I/O Dual Port EtherNet/IP 
Adapter

Catalog numbers 1734-AENTR, 1734-AENTRK, Series C

Catalog numbers with the suffix ‘K’ are conformal coated and their specifications are the 
same as non-conformal coated catalogs.

Table of Contents

Topic

Page

Important User Information 

2

Environment and Enclosure

3

Preventing Electrostatic Discharge

3

North American Hazardous Location Approval

4

European Hazardous Location Approval

4

About the Adapter

6

Before You Begin

7

Install the Adapter

8

Thumbwheel Settings

9

Set the Chassis Size

10

Set the Network Address

10

Replace the Adapter

12

Wire the Adapter

14

Interpret Status Indicators

16

Specifications

18

Additional Resources

23

Содержание 1734-AENTR

Страница 1: ...Contents Topic Page Important User Information 2 Environment and Enclosure 3 Preventing Electrostatic Discharge 3 North American Hazardous Location Approval 4 European Hazardous Location Approval 4 A...

Страница 2: ...nstallation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect t...

Страница 3: ...g with a flame spread rating of 5VA or be approved for the application if nonmetallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication...

Страница 4: ...been removed or the area is known to be nonhazardous Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous Secure any external connecti...

Страница 5: ...the surrounding air temperature range of 20 55 C 4 131 F The equipment must not be used outside of this range ATTENTION Use only a soft dry anti static cloth to wipe down equipment Do not use any clea...

Страница 6: ...to support daisy chain or ring and the existing star and tree network topologies POINT I O Dual Port EtherNet IP Adapter Series C WARNING Secure any external connections that mate to this equipment by...

Страница 7: ...AENT or 1734 AENTK Add on Profile used for the 1734 AENTR and 1734 AENTRK Add on Profiles can be downloaded from https www rockwellautomation com rockwellautomation support downloads page Understand...

Страница 8: ...l DIN rail to assure proper grounding The use of other DIN rail materials for example aluminum or plastic that can corrode oxidize or are poor conductors can result in improper or intermittent groundi...

Страница 9: ...ter Module while power is applied Interruption of the backplane can result in unintentional operation or machine motion ATTENTION Allow 25 4 mm 1 in of space between adjacent equipment for adequate ve...

Страница 10: ...he network Internet Protocol IP address in the following ways Use the pen push thumbwheel switches on the adapter Use a Dynamic Host Configuration Protocol DHCP server such as Rockwell Automation Boot...

Страница 11: ...number for example 000 or a value greater than 254 excluding 888 the adapter checks to see if you enabled DHCP Refer to POINT I O and ArmorPOINT I O Dual Port EtherNet IP Adapter User Manual publicati...

Страница 12: ...sure that power is removed or the area is nonhazardous before proceeding WARNING When you connect or disconnect the Removable Terminal Block RTB with field side power applied an electrical arc can oc...

Страница 13: ...mechanism will snap into place 10 Set the node address on the Node Address pen push thumbwheel using a pen tip 11 Insert the end of the terminal block opposite the handle into the base unit noting tha...

Страница 14: ...ll be connected to the internal power bus 0 2 0 1734 AENTR Module Status Network Activity Network Status Point Bus Status System Power Field Power POINT I O Link 1 Activity Status Link 2 Activity Stat...

Страница 15: ...f you connect or disconnect wiring while the field side power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the a...

Страница 16: ...e needs commissioning due to missing incomplete or incorrect configuration Solid green Device operating normally Flashing red Recoverable fault Complete firmware update verify address switches Solid r...

Страница 17: ...ut state Check for I O module failure and controller operation Note This does not apply to POINT Guard I O connection timeout Solid red Duplicate IP address detected Verify IP address setting and corr...

Страница 18: ...d beyond 0 8 A by 1734 EP24DC or 1734 EPAC backplane extension power supplies Add multiple 1734 EP24DC or 1734 EPAC modules to reach the 63 module max 1 Maximum 31 direct connections for standard I O...

Страница 19: ...21 5 BTU hr 28 8V DC Isolation voltage 50V continuous Reinforced Insulation Type between all circuits Type tested 500V AC for 60 s Field power supply 10 28 8V DC 10 A Field power output 10 28 8V DC 9...

Страница 20: ...ue Input voltage rating 24V DC 10 A Input voltage range 10 28 8V DC Field side power max 24V DC 400 mA Inrush current max 6 A for 10 ms Input overvoltage protection Reverse polarity protected POINTBus...

Страница 21: ...ing Vibration IEC 60068 2 6 Test Fc Operating 5 g 10 500 Hz Shock operating IEC60068 2 27 Test Ea Unpackaged Shock 30 g Shock nonoperating IEC60068 2 27 Test Ea Unpackaged Shock 50 g Emissions IEC 610...

Страница 22: ...65 Eu RoHS compliant with EN 50581 Technical Documentation RCM Australian Radiocommunications Act compliant with AS NZS CISPR11 Industrial Emissions Ex European Union 2014 34 EU ATEX Directive complia...

Страница 23: ...al Port EtherNet IP Adapter User Manual publication 1734 UM017 A detailed description of module functionality configuration installation procedure and information on how to use the POINT I O and Armor...

Страница 24: ...will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA DU002 available at http www rockwellautomation com lit...