Rockwell Automation Publication 1791ES-UM001G-EN-P - November 2016
53
Install the Module
Chapter 3
EtherNet/IP Connections
See
for a description of the pins in the EtherNet/IP connector.
Table 8 - EtherNet/IP Connector Pin Descriptions
I/O Connections
For wiring diagrams, see
See
for a description of the pins in the I/O connector.
Figure 21 - I/O Connector Pin Descriptions
Table 9 - Terminal Positions for I/O Field Power
Pin No.
Signal
8
No connection
7
No connection
6
Receive data minus
5
No connection
4
No connection
3
Receive data plus
2
Transmit data minus
1
Transmit data plus
IMPORTANT
Because the I/O connector has a structure that helps prevent incorrect
wiring, make connections at the specified locations that correspond to
the terminal numbers.
Terminal No.
Signal
Terminal No.
Signal
1
Input +24V DC
3
24V DC
(1)
(1) Applies only to catalog number 1791ES-IB8XOBV4 module.
2
Input -24V DC
4
Output -24V DC
8
1
RJ45
18 19 20 21 22 23 24 25 26
27 28 29 30 31 32 33 34
10 11 12 13 14 15 16 17
1 2 3 4 5 6 7 8 9
I/O Field Power: 1 2 3 4