Publication 0160-5.18 - June 2003
6-4
Using 160-DN2 with DeviceNet Scanner
Using RSNetWorx for DeviceNet
(Continued)
Accessing and Editing Parameters
Parameters in the drive and 160-DN2 module can be edited with
RSNetWorx for DeviceNet.
1.
After creating an EDS file, right-click on the icon for the Bulletin
160 SSC drive and 160-DN2 module and select
Properties
. The
Bulletin 160 Drive dialog box appears.
2.
Click the
Parameters
tab (
). If an EDS Editor message
appears, click
Upload
to load the parameter values in the drive to
the computer.
Parameters are displayed in numerical order under Parameter.
You can either scroll through the list, or check the Groups box
and select a specific group of parameters. The available groups
and the numbers of the module parameters will vary based on the
type of drive that is connected to the module.
3.
In the Current Value column, double-click a value to edit it.
4.
Click
Apply
to save changes to the device.
Figure 6.3
Example Bulletin 160 Drive Dialog Box