Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
171
Measurement Definition
Chapter 4
, the maximum RPM values available for each Angular Range
selection are presented.
Configuring Rod Drop Measurements
Rod drop measurements are configured using the controls in
.
Figure 65 - Rod Drop Measurements
Table 35 - Maximum RPM for Angular Range
Angular Range
Max RPM
2
976
4
1953
6
2929
8
3905
10
4882
12
5858
14
6834
16
7811
18
8787
20
9763
Table 36 - Configurable Parameters for Rod Drop Measurements
Parameters
Values
Comments
Units
Select from presented
displacement units
Rod drop measurements are made using eddy current probes. Configuration of the units, time constant, calibration
offset, and sense control are the same as for
measurements.
Time Constant
0.1…60.0 seconds
Calibration Units
EU (0)
Volts (1)
Calibration Offset
-50,000…50,000
Tachometer
0 (Tacho/Speed 0)
1 (Tacho/Speed 1)
Select the source for the tachometer that is used in the rod drop measurement.
Value that is written to the assembly is 1 or 2, 0 = off (to the module).
Содержание 1444-AOFX00-04RB
Страница 10: ...10 Rockwell Automation Publication 1444 UM001D EN P June 2018 Table of Contents Notes...
Страница 12: ...12 Rockwell Automation Publication 1444 UM001D EN P June 2018 Preface Notes...
Страница 198: ...198 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 5 Configure the Tachometer Expansion Module Notes...
Страница 210: ...210 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 7 Configure Relays Notes...
Страница 230: ...230 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 8 Configure Alarms Notes...
Страница 240: ...240 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 9 Trend and Transient Capture Notes...
Страница 316: ...316 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 10 Operate the Module Notes...
Страница 549: ......