background image

Input RFI Filters

5

1336 PLUS, 

PLUS

 

II,

 FORCE and 

IMPACT Filter Installation

Use the cross reference below to verify that the correct filter has been 
selected for your CE compatible drive. In addition, ensure that the 
drive was ordered with the “-AE” enclosure option or the EMC 
Enclosure Kit (1336x-AEx) has been properly installed.

Filter Selection

Components Included with Filter

Filter Catalog
Number

Filter 
Series

Mounting

See . . .
(pg. 11-13)

Power 
Diss.
(Watts)

Three-Phase
Volts

Used with . . .

Frame
Reference

1336 PLUS/

PLUS

 

II

1336 FORCE

1336 IMPACT

1336-RFB-7-AA

A

Figure 1

4.5

200-240V

1336S/F-AQF05 - AQF10

N/A

1336E-AQF05 - AQF10

A1

380-480V

1336S/F-BRF05 - BRF20

1336E-BRF05 - BRF20

A1-A2

1336-RFB-7-A

B

Figure 1 or 
Figure 2

2

200-240V

1336S/F-AQF05 - AQF10

1336E-AQF05 - AQF10

A1

380-480V

1336S/F-BRF05 - BRF20

1336E-BRF05 - BRF20

A1-A2

1336-RFB-16-AA

A

Figure 1

9

200-240V

1336S/F-AQF15 - AQF20

1336E-AQF15 - AQF20

A2

380-480V

1336S/F-BRF30 - BRF50

1336E-BRF30 - BRF50

A2-A3

1336-RFB-16-A

B

Figure 1 or 
Figure 2

9.5

200-240V

1336S/F-AQF15 - AQF20

1336E-AQF15 - AQF20

A2

380-480V

1336S/F-BRF30 - BRF50

1336E-BRF30 - BRF50

A2-A3

1336-RFB-30-A

A

Figure 1

14

200-240V

1336S/F-AQF30 - AQF50

1336E-AQF30 - AQF50

A3

1336-RFB-30-A4

A

Figure 2

35

380-480V

1336S/F-BRF75 - BRF200

1336E-BRF75 - BRF100 A4

1336-RFB-27-B

A

Figure 2

30

200-240V

1336S/F-A007

1336T-A001 - A007

1336E-A007

B

380-480V

1336S/F-B007 - B015

1336T-B001 - B015

1336E-B007 - B015

B

1336-RFB-48-B

A

Figure 2

56

200-240V

1336S/F-A010 - A015

1336T-A010 - A015

1336E-A010 - A015

B

380-480V

1336S/F-B020 - B030

1336T-B020 - B030

1336E-B020 - B030

B

1336-RFB-80-C

A

Figure 2

71

200-240V

1336S/F-A020 - A030

1336T-A020 - A030

1336E-A020 - A030

C

380-480V

1336S/F-BX040 - BX060

1336T-BX040 - BX060 1336E-BX040 - BX060

C

1336-RFB-150-D

A

Figure 3 or 
Figure 4

90

200-240V

1336S/F-A040 - A050

1336T-A040 - A050

1336E-A040 - A050

D

380-480V

1336S/F-B060 - B100

1336T-B060 - B100

1336E-B060 - B100

D

1336-RFB-180-D

A

Figure 3 or 
Figure 4

125

200-240V

1336S/F-A060

1336T-A060

1336E-A060

D

380-480V

1336S/F-B125 - BX150

1336T-B125 - BX150

1336E-B125 - BX150

D

1336-RFB-340-E

A

Figure 3 or 
Figure 4

60

200-240V

1336S/F-A075 - A125

1336T-A075 - A125

1336E-A075 - A125

E

380-480V

1336S/F-B150 - B250

1336T-B150 - B250

1336E-B150 - B250

E

1336-RFB-475-G

A

Figure 5

61

380-480V

1336S/F-BP250 - BP350
1336F-BPR250 - BPR350

N/A

1336E-BP300 - BP350
1336E-BPR300 - BPR350

F

1336S/F-BX250 - B350

1336T-BX250 - B350

1336E-BX250 - B350

G

1336-RFB-590-G

A

Figure 5

94

380-480V

1336S/F-BP400 - BP450
1336F-BPR400 - BPR450

N/A

1336E-BP400 - BP450
1336E-BPR400 - BPR450

F

1336S/F-B400 - B450

1336T-B400 - B450

1336E-B400 - B450

G

1336-RFB-670-G

A

Figure 5

121

380-480V

1336S/F-B500 - B600

1336T-B500 - B600

1336E-B500 - B600

G

Item

Quantity - 1336-RFB- . . .

7-A, 16-A, 30-A 

30-A4, 27-B, 48-B, 80-C

150-D, 180-D, 340-E

475-G, 590-G, 670-G

Filter

1

1

1

1

EMT Conduit

1

1

EMT Conduit Fitting

1

2

Bolts

4

8

3

Flat Washers

4

Star Washers

4

Terminal Block Housing

1

Standoffs

2

Nuts

3

4

3

E

ng
lis

h

Содержание 1305-RFB-12-C

Страница 1: ...User Manual Input RFI Filters...

Страница 2: ......

Страница 3: ...y Sales Representative Refer to the page listed below for installation instructions 1305 See page 2 1336 PLUS PLUS II FORCE and IMPACT See page 5 ATTENTION The Input RFI Filter connects between the in...

Страница 4: ...05 MP 08 B 1305 RFB 12 C 10 3 Watts 200 480V 1305 AA12A BA09A 1305 MP 12 C Item Quantity Filter w Output Cable 1 Grounding Bracket 1 Metal Conduit Panel 1 Terminal Block Cover 1 Terminal Block Cover A...

Страница 5: ...onnection must be provided as shown on the following page NEMA Type 1 only Before connecting the AC input lines slide the Terminal Block Cover Adapter onto the wire After wiring has been completed sli...

Страница 6: ...r case ground 1305 Knockout Definitions Dimensions are in Millimeters and Inches ATTENTION To guard against possible equipment damage RFI filters can only be used with AC supplies that are nominally b...

Страница 7: ...80V 1336S F B007 B015 1336T B001 B015 1336E B007 B015 B 1336 RFB 48 B A Figure 2 56 200 240V 1336S F A010 A015 1336T A010 A015 1336E A010 A015 B 380 480V 1336S F B020 B030 1336T B020 B030 1336E B020 B...

Страница 8: ...11 42 320 0 12 60 F 180 0 7 09 230 0 9 06 280 0 11 02 H 225 0 8 86 275 0 10 83 305 0 12 00 All Dimensions in Millimeters and Inches D TB Cover 50 0 1 97 x 41 0 1 61 x 66 0 2 60 A C Weight kg lbs 1 1...

Страница 9: ...75 All Dimensions in Millimeters and Inches Weight kg lbs 25 0 55 1 37 0 81 6 E G C B D H H F Conduit Fitting A Catalog Number 1336 RFB 30 A4 1336 RFB 27 B 1336 RFB 48 B 1336 RFB 80 C A 260 1 10 24 27...

Страница 10: ...22 0 4 08 122 0 4 08 F B 5 0 0 20 Dia Ground Stud H D C A G Catalog Number 1336 RFB 475 G 1336 RFB 590 G 1336 RFB 670 G A 300 0 11 81 B 794 0 31 26 C 160 0 6 30 D 275 0 10 83 E 200 0 7 87 F 70 0 2 76...

Страница 11: ...nt the drive to the panel using the Mounting diagram provided in this document as a guide Drive mounting information can be found in the User Manual b Using the Dimension and Mounting diagrams provide...

Страница 12: ...effective and to reduce cable radiation all cables entering and or exiting the filter drive must be shielded or armored The ground conductor of the motor cable drive end must be connected directly to...

Страница 13: ...catalog numbers To Motor1 Cable Supplied with Filter1 Conduit1 To Motor1 Three Phase Input1 Access Panel Flat Washer Star Washers Bolt Bolt Important Drive and filter must be mounted to a common back...

Страница 14: ...5 for frame references and corresponding catalog numbers Conduit Box1 To Motor1 Access Panel and Input Terminal Block Lower Access Panel Important Drive and filter must be mounted to a common back pl...

Страница 15: ...portant This information represents the method used to mount 1336 RFB 475 590 670 filters in an Allen Bradley supplied EMC enclosure User supplied EMC enclosures must follow all of the guidelines show...

Страница 16: ...Control I O Filter Input Filter Input Filter Input Filter Input SCANport Motor Output Motor Output Motor Output Motor Output SCANport SCANport SCANport Side of Drive Control I O 28 6 34 9 1 13 1 38 3...

Страница 17: ......

Страница 18: ...Publication RF 101ML EN December 1999 P N 74103 446 01 06 Supersedes July 1999 Copyright 1999 Rockwell International Corporation All rights reserved Printed in USA...

Отзывы: