background image

 

ALLEN

&

HEATH

           XB-14 service manual                  AP7566

  

            Page - 5 - of 13

 

 

  

 Servicing Precautions – General Notes 

 

Service personnel:

   

Service work should be carried out by technically qualified service personnel only.  
Mains power is dangerous and can kill.  Do not attempt to work on a linear or switched 
mode power supply if you are not suitably qualified to do so.  Do not attempt to repair 
surface mount circuit assemblies unless you are suitably qualified and have the 
necessary facilities to do so.  Replacement circuit assemblies can be ordered. 

Service facilities:

   

Ensure a suitably sized work surface is available.  Ensure this is clear of dirt, debris and 

obstructions which may damage the equipment surfaces.  Ensure adequate lighting.  
Use the correct tools for the job and ensure they are in good working order.  Ensure all 
workshop safety requirements are adhered to. 

Service information: 

Check that you have all the information you need before starting the service job.  Refer 

to the Allen & Heath web site or contact Allen & Heath technical support for details on 
the latest information.  Full technical information can be downloaded from the web site 
Distributor Zone (password required). 

Mains power:

 

 

Connect the equipment to mains power only of the type described in the user guide and 

marked on the rear panel.  The power source must provide a good ground connection.  
Ensure you always use an isolation transformer when working on any mains power 
supply unit. 

Mains cord and fuse:

 

 

Use the correct power cord as supplied with the equipment.  Do not remove or tamper 

with the ground connection in the power cord.  Heed the Important Mains Plug Wiring 
Instructions printed in the user guide if it is necessary to rewire the mains cord.  Always 
replace the equipment mains fuse with the correct type and rating as described in the 
user guide and marked on the equipment panel. 

Opening the unit:

   

Switch off and remove the mains power cord before opening the equipment.  Ensure all 

power supply covers and safety shields are in place before applying power with the unit 
open for diagnostic fault finding. 

Closing the unit:

 

 

Before finishing, check the quality and accuracy of the service work carried out.  

Remove any dirt or debris as this may cause equipment failure in the future.  Ensure all 
assemblies, harnesses and connectors are correctly aligned and plugged in.  Ensure 
that jumper settings and control configurations are correctly set according to the 
requirements of the customer. 

Continued - 

 
 

Содержание XB-14

Страница 1: ...anual AP7566 Page 1 of 13 ALLEN HEATH SERVICE MANUAL Copyright 2009 Allen Heath Limited All rights reserved Allen Heath Limited Kernick Industrial Estate Penryn Cornwall TR10 9LU UK http www allen hea...

Страница 2: ...t has been installed and operated in accordance with the instructions in this User Guide The equipment has not been subject to misuse either intended or accidental neglect or alteration other than as...

Страница 3: ...XB 14 service manual AP7566 Page 3 of 13 CONTENTS DEVELOPMENT CHANGES SERVICING PRECAUTIONS AND GENERAL NOTES PARTS IDENTIFICATION How to order parts Exterior parts Interior parts SOFTWARE FIRMWARE SP...

Страница 4: ...OPMENT CHANGES NOTE These changes have been implemented at the factory as part of our ongoing development policy They are not critical to the basic function of the unit It is for the owner service eng...

Страница 5: ...stributor Zone password required Mains power Connect the equipment to mains power only of the type described in the user guide and marked on the rear panel The power source must provide a good ground...

Страница 6: ...igned flight case if you need to ship the unit To avoid injury to yourself or damage to the equipment take care when lifting moving or carrying the equipment Operation To test the console make sure it...

Страница 7: ...t of UK service centres can be viewed at http www allen heath com UK service_centres asp PARTS IDENTIFICATION EXTERIOR PARTS Side moulding AA6741L AL6741R Blue AJ2075A Burgundy AJ6949 Black AJ6106A La...

Страница 8: ...LEN HEATH XB 14 service manual AP7566 Page 8 of 13 Blue AJ6237 Bal AI8008 USB RTN AI8007 RCA phono AL6830 Stereo gain AI8007 Aux AI8003 Stereo fader 003 941 EQ HF LF AI8006 USB AL6096 Black rect AJ718...

Страница 9: ...ALLEN HEATH XB 14 service manual AP7566 Page 9 of 13 CRM speakers CRM phones MIX B level AI8007 Master fader 003 941 Burgundy AJ6950 Mono out AL4895 Guest phones AI8007...

Страница 10: ...ALLEN HEATH XB 14 service manual AP7566 Page 10 of 13 INTERIOR PARTS Mono ip 003 900 Telco 1 003 901 Telco 2 003 933 Stereo 003 902 USB 003 903...

Страница 11: ...ALLEN HEATH XB 14 service manual AP7566 Page 11 of 13 Logic 003 904 Mix 003 905 Master 003 906 Meter R 003 907...

Страница 12: ...ALLEN HEATH XB 14 service manual AP7566 Page 12 of 13 Distribution 003 908 Connector 003 908...

Страница 13: ...PGM L R out 0dB gain 0dBu 1kHz 0 004 Stereo in to PGM out 0dB gain 10dBu 1kHz 0 003 USB Audio CODEC Coder Decoder USB Audio In Out USB 1 1 compliant 16bit Sample Rate 32 44 1 or 48kHz Noise Mic Pre EI...

Отзывы: