WZ
3
1442
SYS-LINK Option Fitting Instructions AP5737
3
Step 3:
Open the connector panel
Remove the two M3x6 Torx screws from each
side of the connector panel. Remove the six
M3x6 Torx screws from the rear of the connector
panel. Carefully tilt the connector panel away
from the console so that it is flat on the work
surface.
Step 4:
Remove the clamp bracket
and blanking plate
Remove the five M3 nuts that fix the clamp
bracket to the connector pod chassis. Remove
the clamp bracket. Remove the three M3
blanking plate screws from the rear of the
connector pod. Remove the blanking plate.
Step 5:
Fit the SYS-LINK card to the
console
The SYS-LINK circuit card assembly is fixed to
the connector panel using four M4 D-type
connector nuts. These are supplied already
fitted to the card’s sockets. Remove the nuts
and place the card into the connector panel
slots, observing the correct orientation. Secure
the SYS-LINK card by refitting the D-type nuts,
ensuring that they are fully tightened.
Step 6:
Connect the SYS-LINK power
The option gets its power from the c15V
and -15V rails.
Hand solder the SYS-LINK card’s sleeved red
and black wires to the connector card: red to pin
P1 (+15) and black to pin P2 (-15). Check that
the solder joints are of good quality. Cable tie
the wires at point 1 (see diagram).
REMOVE 6x M3 TORX SCREWS
EXTERNAL DC IN
ONLY USE RECOMMENDED ALLEN&HEATH POWER SUPPLY.
REFER TO USER GUIDE FOR DETAILS.
WARNING: THIS APPARATUS MUST BE EARTHED
DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
RISK OF ELECTRIC SHOCK
CAUTION
DO NOT OPEN
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
100 - 240V~ 47-63Hz 45W MAX
AC MAINS IN ~
FUSE
T630mA L 250V 20mm
ON
I
0
OFF
Made in the UK by ALLEN & HEATH Limited
Serial No.
BACKUP SUPPLY
9
A
9
10
G4
B
AUX 6
R
R
L
SENDS
G2
G3
G1
AUX
REVERSE
GRP/AUX
INSERT
INSERT
3
A3
OUT
4
OUT
A4
LISTEN WEDGE
MATRIX OUT
RETURN
R
L
MONITOR OUT
OUT
L
M
R
2-TRACK
L
SEND
A5
INSERT
R
OUT
A6
OUT
INSERT
L
13-14
A1
INSERT
2
OUT
A2
OUT
INSERT
1
ST4
ST3
L/M
R
R
L/M
MIC
LINE IN
OUT
DIRECT
10
INSERT
L/M
ST2
R
R
ST1
11-12
L/M
OUT
DIRECT
MIC
LINE IN
9
10
INSERT
1
2
3
4
5
6
7
8
MIC
LINE IN
OUT
DIRECT
INSERT
MIC
LINE IN
OUT
DIRECT
8
INSERT
8
OUT
DIRECT
MIC
LINE IN
7
6
7
INSERT
OUT
DIRECT
MIC
LINE IN
5
6
INSERT
5
LINE IN
OUT
DIRECT
MIC
4
INSERT
4
LINE IN
DIRECT
INSERT
OUT
DIRECT
LINE IN
MIC
3
OUT
MIC
2
INSERT
3
DIRECT
OUT
LINE IN
MIC
1
2
INSERT
1
- IN
+IN
3
INPUT
2
1
RING -IN
RING
TIP +IN
TIP
LINE
MIC
TIP
RING
SEND
RETURN
XLR OUT
- OUT
3
2
1
INSERT
+OUT
SYS-LINK OUT ( option )
SYS-LINK IN ( option )
MixWizard WZ
3
14:4:2
AUX 5
AUX 4
AUX 3
AUX 2
AUX 1
ALLEN&HEATH
REMOVE 2x M3 TORX SCREWS PER SIDE
9
10
OUT
DIRECT
OUT
DIRECT
4
5
6
7
8
OUT
DIRECT
OUT
DIRECT
OUT
DIRECT
OUT
DIRECT
OUT
DIRECT
SYS-LINK OUT ( option )
SYS-LINK IN ( option )
SYS-LINK CARD IN PLACE
SECURED WITH 4x D-TYPE NUTS
9
10
OUT
DIRECT
OUT
DIRECT
4
5
6
7
8
OUT
DIRECT
OUT
DIRECT
OUT
DIRECT
OUT
DIRECT
OUT
DIRECT
SYS-LINK OUT ( option )
SYS-LINK IN ( option )
REMOVE 3x M3 TORX SCREWS
AND BLANKING PLATE
REMOVE 5x M3 NUTS AND BRACKET
CN4
CN3
P2
P1
1
CABLE TIE WIRES AT POINT 1
RED
BLACK
SOLDER POWER HARNESS WIRES
TO PADS ON CONNECTOR CARD
RED TO P1, BLACK TO P2
P1
P2