WZ
3
16:2 / WZ
3
12:2 / WZ
3
20S
SYS-LINK Option Fitting Instructions AP5735
1
These are the instructions for fitting the SYS-LINK Version 2 console expander option to the
MixWizard
WZ
3
16:2,
WZ
3
12:2
and
WZ
3
20S
consoles. Two consoles, each with SYS-LINK V2 installed, may be linked
together using a single 37 way cable such that one becomes a channel expander (slave) to the other
(master). This links all the mix buses and the PFL/AFL system. The
WZ
3
16:2, WZ
3
12:2
and
WZ
3
20S
have
an output connector only and should therefore be used as a slave. The cable is not supplied but may be
ordered separately or sourced elsewhere. Fitting the option requires removal of the rear connector cover
to access the internal assemblies, installation of a circuit card assembly and ribbon harness, and some
soldering. This work should be carried out by technically competent personnel.
For information on how to use SYS-LINK please refer to the Applications Note AP5736. For information
on using the
WZ
3
16:2
and
WZ
3
12:2
consoles refer to User Guide AP5331. For information on using the
WZ
3
20S
console refer to User Guide AP6318. Should further assistance be required, please contact Allen
& Heath Technical Support (details on our web site www.allen-heath.com).
Before Starting
Read these fitting instructions carefully before starting. For trouble free installation and operation heed all
the precautions noted. The console must be fully unplugged and removed from its rack, plinth or other
furniture before carrying out the work. Normal workshop tools are required. These include Pozi
(crosshead) and Torx (starhead) screwdrivers, and a fine tipped soldering iron. Provide a suitably large,
well lit work surface such as a service workshop bench. To avoid damage to the cosmetics of the
console ensure that the work surface is clean and clear of obstructions. Allow enough time to carry out
the work properly and test the results.
Check the Contents
The following parts are packed with the kit:
003-260 x1 SYS-LINK V2 circuit assembly
with power harness. The panel fixing nuts are
fitted to the D-connector socket.
AL5489 x1 2-connector IDC ribbon harness
AP5736 x1 SYS-LINK V2 Applications Note.
IMPORTANT
:
Any changes or modifications
to the equipment not approved by Allen & Heath
could void the compliance of the equipment.
Whilst we believe the information in these
instructions to be reliable we do not assume
responsibility for inaccuracies. We also reserve
the right to make changes in the interest of
further product development.
Copyright© 2005 Allen & Heath Limited. All rights
reserved. www.allen-heath.com
This work should be carried out by
competent technical personnel only.
Disconnect the mains power cord before
opening the unit.
Take care not to damage the panels or
internal assemblies during fitting. Prevent
loose parts or dirt from entering the console
as this may cause equipment failure.
ALLEN
&
HEATH WZ
3
16:2 / WZ
3
12:2 / WZ
3
20S SYS-LINK
AP5735 issue 2
Fitting Instructions for the W312/16-SLV2 Kit
Option fits here
IT IS RECOMMENDED THAT THIS OPTION IS FITTED BY AN APPROVED ALLEN & HEATH SERVICE AGENT