SYS-LINK Option Fitting Instructions   AP5735 

 

 

         1 

 
 
 
 
 
 
 
 
 
 

 

 

 

These are the instructions for fitting the SYS-LINK Version 2 console expander option to the 

MixWizard

 

WZ

3

16:2,

 

WZ

3

12:2

 and 

WZ

3

20S 

consoles.  Two consoles, each with SYS-LINK V2 installed, may be linked 

together using a single 37 way cable such that one becomes a channel expander (slave) to the other 

(master).  This links all the mix buses and the PFL/AFL system.  The 

WZ

3

16:2, WZ

3

12:2

 and

 WZ

3

20S 

have 

an output connector only and should therefore be used as a slave.  The cable is not supplied but may be 
ordered separately or sourced elsewhere.  Fitting the option requires removal of the rear connector cover 
to access the internal assemblies, installation of a circuit card assembly and ribbon harness, and some 
soldering.  This work should be carried out by technically competent personnel. 

For information on how to use SYS-LINK please refer to the Applications Note AP5736.  For information 

on using the 

WZ

3

16:2

 and

 WZ

3

12:2

 consoles refer to User Guide AP5331.  For information on using the 

WZ

3

20S 

console refer to User Guide AP6318.  Should further assistance be required, please contact Allen 

& Heath Technical Support (details on our web site www.allen-heath.com). 

Before Starting     

Read these fitting instructions carefully before starting.  For trouble free installation and operation heed all 
the precautions noted.  The console must be fully unplugged and removed from its rack, plinth or other 
furniture before carrying out the work.  Normal workshop tools are required.  These include Pozi 
(crosshead) and Torx (starhead) screwdrivers, and a fine tipped soldering iron.  Provide a suitably large, 

well lit work surface such as a service workshop bench.  To avoid damage to the cosmetics of the 
console ensure that the work surface is clean and clear of obstructions.  Allow enough time to carry out 
the work properly and test the results. 

Check the Contents 

The following parts are packed with the kit: 

003-260 x1   SYS-LINK V2 circuit assembly 
with power harness.  The panel fixing nuts are 
fitted to the D-connector socket. 

AL5489 x1  2-connector IDC ribbon harness 

AP5736 x1 SYS-LINK V2 Applications Note. 

 

IMPORTANT

:

   Any changes or modifications 

to the equipment not approved by Allen & Heath 
could void the compliance of the equipment.  
Whilst we believe the information in these 

instructions to be reliable we do not assume 
responsibility for inaccuracies. We also reserve 
the right to make changes in the interest of 
further product development. 

Copyright© 2005 Allen & Heath Limited. All rights 

reserved.         www.allen-heath.com 

 

This work should be carried out by 

competent technical personnel only. 

 

Disconnect the mains power cord before 

opening the unit. 

 

Take care not to damage the panels or 

internal assemblies during fitting.  Prevent 
loose parts or dirt from entering the console 
as this may cause equipment failure. 

   ALLEN

&

HEATH         WZ

3

16:2 / WZ

3

12:2 / WZ

3

20S  SYS-LINK    

AP5735 issue 2

    Fitting Instructions for the W312/16-SLV2 Kit

 

Option fits here 

IT IS RECOMMENDED THAT THIS OPTION IS FITTED BY AN APPROVED ALLEN & HEATH SERVICE AGENT