 Servicing Precautions – General Notes 

 

Service personnel:

   

Service work should be carried out by technically qualified service personnel only.  
Mains power is dangerous and can kill.  Do not attempt to work on a linear or switched 
mode power supply if you are not suitably qualified to do so.  Do not attempt to repair 
surface mount circuit assemblies unless you are suitably qualified and have the 
necessary facilities to do so.  Replacement circuit assemblies can be ordered. 

Service facilities:

   

Ensure a suitably sized work surface is available.  Ensure this is clear of dirt, debris and 

obstructions which may damage the equipment surfaces.  Ensure adequate lighting.  
Use the correct tools for the job and ensure they are in good working order.  Ensure all 
workshop safety requirements are adhered to. 

Service information: 

Check that you have all the information you need before starting the service job.  Refer 

to the Allen & Heath web site or contact Allen & Heath technical support for details on 
the latest information.  Full technical information can be downloaded from the web site 
Distributor Zone (password required). 

Mains power:

 

 

Connect the equipment to mains power only of the type described in the user guide and 

marked on the rear panel.  The power source must provide a good ground connection.  
Ensure you always use an isolation transformer when working on any mains power 
supply unit. 

Mains cord and fuse:

 

 

Use the correct power cord as supplied with the equipment.  Do not remove or tamper 

with the ground connection in the power cord.  Heed the Important Mains Plug Wiring 
Instructions printed in the user guide if it is necessary to rewire the mains cord.  Always 
replace the equipment mains fuse with the correct type and rating as described in the 
user guide and marked on the equipment panel. 

Opening the unit:

   

Switch off and remove the mains power cord before opening the equipment.  Ensure all 

power supply covers and safety shields are in place before applying power with the unit 
open for diagnostic fault finding. 

Closing the unit:

 

 

Before finishing, check the quality and accuracy of the service work carried out.  

Remove any dirt or debris as this may cause equipment failure in the future.  Ensure all 
assemblies, harnesses and connectors are correctly aligned and plugged in.  Ensure 
that jumper settings and control configurations are correctly set according to the 
requirements of the customer. 

Continued - 

 
 

Содержание iDR0

Страница 1: ...ce manual AP7233_1 Page 1 of 9 ALLEN HEATH SERVICE MANUAL Copyright 2008 Allen Heath Limited All rights reserved Allen Heath Limited Kernick Industrial Estate Penryn Cornwall TR10 9LU UK http www alle...

Страница 2: ...t has been installed and operated in accordance with the instructions in this User Guide The equipment has not been subject to misuse either intended or accidental neglect or alteration other than as...

Страница 3: ...iDR 0 service manual AP7233_1 Page 3 of 9 CONTENTS DEVELOPMENT CHANGES SERVICING PRECAUTIONS AND GENERAL NOTES PARTS IDENTIFICATION How to order parts Parts SOFTWARE FIRMWARE Must run 1 21 or later SP...

Страница 4: ...LOPMENT CHANGES NOTE These changes have been implemented at the factory as part of our ongoing development policy They are not critical to the basic function of the unit It is for the owner service en...

Страница 5: ...stributor Zone password required Mains power Connect the equipment to mains power only of the type described in the user guide and marked on the rear panel The power source must provide a good ground...

Страница 6: ...igned flight case if you need to ship the unit To avoid injury to yourself or damage to the equipment take care when lifting moving or carrying the equipment Operation To test the console make sure it...

Страница 7: ...heath com UK distributors asp UK parts must be ordered through an appointed A H dealer or service centre A list of UK service centres can be viewed at http www allen heath com UK service_centres asp...

Страница 8: ...LEN HEATH iDR 0 service manual AP7233_1 Page 8 of 9 Fan Grill AA5359 Button AA2887 DC socket AL8100 Fuse holder AA3178 AC switch AL3338 AC inlet AA3458 Temperature sense PCB 003 254 RJ45 socket AL4486...

Страница 9: ...fibre dual redundant systems MIDI mix rack and surface PL Anet for A H PL Series controllers mix rack and surface Digital signal processing module 48kHz sampling 24 bit 48 bit data in EQ processing S...

Отзывы: