DR128 SysNet

 Fitting Instructions 

AP3165 issue 4 

 

 

Fitting Procedure 

 

Step 1 

Check which version of PIC you need.  The V4 part is 
fitted as standard.  If you need to run the earlier V2 
version then carefully unplug the 28-pin integrated 
circuit and replace it with the V2 version supplied.  
Make sure  its pin 1 is positioned as shown and the pins 
are correctly aligned and pressed in. 

 

 

Step 2 

Turn off power to the DR128 and unplug the mains 
cable.  Remove the 6 fixing screws as shown and lift off 
the top cover. 

 

 

Step 3 

Remove the rear panel SysNet option slot blanking 
plate by unscrewing the two fixing screws. 

Locate and carefully unplug the 26way harness that 
connects between the CPU and Lower Connector 
circuits. 

 

 

Step 4 

Fit the SysNet card and mounting bracket to the DR128 
using the fixing screws attached to the mounting 
bracket. 

Fold and position the new 26way harness as shown 
plugging it into the CPU, Lower Connector and SysNet 
cards.  

Make sure the harness pins are correctly aligned with 
the mating connector pins.  Push the plugs fully home. 

Check that the harness is neatly folded with the pin 1 
red stripe correctly positioned as shown below. 

 

 

Step 5 

Check your work and refit the top cover.  Power up the 
DR128 and check that it boots up correctly. 

 

Refer to the relevant SysNet Protocol document for 
details on programming the remote controller.  For 
instructions on programming and operating the remote 
controller refer to the supplier of that equipment. 

 