DM0 MixRack Getting Started Guide
10
AP10972 Issue 1
5.3
ME system connection
Plug a touring grade CAT5e (or higher specification) cable up to 100m long between the MixRack ME port
and the ME-1 or ME-U.
Refer to
www.allen-heath.com
for cable requirements, recommendations, and a list
of CAT5 cables available to order.
5.4
Connect a laptop or wireless router
Connect a laptop, router or access point to either of the Network ports to use with dLive Editor or iOS apps.
Read the Release Notes and Help Files accompanying the software or apps for further information.
dLive communicates over TCP/IP. All devices on the network including the MixRack
and Surface must have compatible IP addresses. Factory defaults are:
MixRack
192.168.1.70
Surface
192.168.1.71
Subnet Mask
255.255.255.0
Gateway
192.168.1.254
For direct, wired laptop connections, set your laptop to a static, compatible IP
address, for example 192.168.1.10.
For wireless connections, set your router / access point to a compatible IP address,
for example 192.168.1.254, and its DHCP range to a compatible range of addresses,
for example 192.168.1.100 to 192.168.1.200. Set any wireless laptop or mobile device
to DHCP / ‘obtain an IP address automatically’.