Continuous-Time Ratiometric
Linear Hall Effect Sensors
A1301
and
A1302
3
Allegro MicroSystems, Inc.
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com
DEVICE CHARACTERISTICS
over operating temperature range, T
A
, and V
CC
= 5 V, unless otherwise noted
Characteristic
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Electrical Characteristics
Supply Voltage
V
CC
Running, T
J
< 165°C
4.5
–
6
V
Supply Current
I
CC
Output open
–
–
11
mA
Output Voltage
V
OUT(High)
I
SOURCE
= –1 mA, Sens = nominal
4.65
4.7
–
V
V
OUT(Low)
I
SINK
= 1 mA, Sens = nominal
–
0.2
0.25
V
Output Bandwidth
BW
–
20
–
kHz
Power-On Time
t
PO
V
CC(min)
to 0.95 V
OUT;
B = ±1400 G;
Slew rate = 4.5 V/
μ
s to 4.5 V/100 ns
–
3
5
μ
s
Output Resistance
R
OUT
I
SINK
≤
1 mA, I
SOURCE
≥
–1 mA
–
2
5
Ω
Wide Band Output Noise, rms
V
OUTN
External output low pass filter
≤
10 kHz;
Sens = nominal
–
150
–
μ
V
Ratiometry
Quiescent Output Voltage Error
with respect to
Δ
V
CC
1
Δ
V
OUTQ(V)
T
A
= 25°C
–
–
±3.0
%
Magnetic Sensitivity Error with
respect to
Δ
V
CC
2
Δ
Sens
(V)
T
A
= 25°C
–
–
±3.0
%
Output
Linearity
Lin
T
A
= 25°C
–
–
±2.5
%
Symmetry
Sym
T
A
= 25°C
–
–
±3.0
%
Magnetic Characteristics
Quiescent Output Voltage
V
OUTQ
B = 0 G; T
A
= 25°C
2.4
2.5
2.6
V
Quiescent Output Voltage over
Operating Temperature Range
V
OUTQ(
Δ
T
A
)
B = 0 G
2.2
–
2.8
V
Magnetic Sensitivity
Sens
A1301; T
A
= 25°C
2.0
2.5
3.0
mV/G
A1302; T
A
= 25°C
1.0
1.3
1.6
mV/G
Magnetic Sensitivity over
Operating Temperature Range
Sens
(
Δ
T
A
)
A1301
1.8
–
3.2
mV/G
A1302
0.85
–
1.75
mV/G
1
Refer to equation (4) in Ratiometric section on page 4.
2
Refer to equation (5) in Ratiometric section on page 4.