Allegro Industries 9910 Series Скачать руководство пользователя страница 3

 

INTRODUCTION

 

 

This manual provides instructions for the use and maintenance of the ALLEGRO INDUSTRIES 

Continuous-Flow Supplied Air Hood Respirator.  You must read and understand this manual and be 
trained in the proper use of the equipment before using it in a contaminated atmosphere. 
 

FOR MORE INFORMATION ON ALLEGRO INDUSTRIES’ PRODUCTS, OR 

FOR OUR PARTS CATALOG, CONTACT ALLEGRO INDUSTRIES 

TECHNICAL SERVICE TOLL FREE AT (800) 622-3530 or 

[email protected]

 
 
 
 

 

DESCRIPTION

 

 

The ALLEGRO INDUSTRIES Continuous-Flow Supplied Air Hood Respirator provides a constant 

flow of air to the hood when connected to an external air source.  When used with an approved air line 
at a pressure of 6 to 40 PSI, air is delivered to the respirator at a rate exceeding 6 CFM (170 liters per 
minute) (See NIOSH approval label). 
 

 

SAFETY PRECAUTIONS 

 

To protect your life and health and to prevent serious injury or death, this respirator must be selected for 
your specific application, so that it fits properly; and must be used, inspected, and maintained as directed 
in this manual. 
 
 

 

 

 

 

 

 

 

 

 

 

Industrial Hygienists, Safety Engineers, Occupational Physicians, Medical Department or Supervisor are
among those professionals who should be consulted to be sure that you are wearing the proper respirator 
for the protection needed. Hoods are a type of respirator.

 

Содержание 9910 Series

Страница 1: ...UPPLIED AIR HOOD RESPIRATORS P N 9910 P N 9910R P N 9910D P N 9910DS P N 9912D Read and understand all instructions before using this product Open carton carefully and inspect product for damage cause...

Страница 2: ...Safety Precautions Warnings and Limitations Cautions and Limitations Parts List Air Quality and Volume Inlet Pressure Donning Doffing Instructions Hood Replacement Maintenance and Storage Specificatio...

Страница 3: ...nstant flow of air to the hood when connected to an external air source When used with an approved air line at a pressure of 6 to 40 PSI air is delivered to the respirator at a rate exceeding 6 CFM 17...

Страница 4: ...used 7 This respirator shall not be used in any manner contrary to the recommendations contained on the package label and on the Material Safety Data Sheet MSDS or similar document available from the...

Страница 5: ...ators S Special or Critical User Instructions and or specific use limitations apply Refer to User Instructions before donning S SPECIAL OR CRITICAL USER S INSTRUCTIONS Dual Hose Usage The blue unrelat...

Страница 6: ...9910 02 Head Band Assembly Standard 3B 9910 03 Head Band Assembly Ratchet Optional 4 9910 25A Peel Off Lens Cover Not Shown 9910 04 Breathing Tube Assy w o Waist Belt Not Shown 9900 02 Waist Belt 5A...

Страница 7: ...Attachment and the length of the supplied air hose see Special User Instructions Warning ALLEGRO INDUSTRIES air hose is approved for use with this Supplied Air Hood Respirator Using any other hose wil...

Страница 8: ...e breathing tube into the replacement hood Be sure to insert the breathing tube fully into the collar of the hood See drawing Underside View Underside View for 9910 9910R 7 Install the white clamp ove...

Страница 9: ...pirator and may result in bodily injury or death The hood and its components used by an individual should be inspected and if possible cleaned and sanitized after each day of use The 9910D and 9910DS...

Страница 10: ...r to those components listed on the NIOSH label in this manual STORAGE Store the Supplied Air Hood away from dust sunlight temperature extremes moisture and chemicals Before storing these hood assembl...

Страница 11: ...ect indirect incidental special or consequential arising out of sale use or misuse of ALLEGRO INDUSTRIES products or the user s inability to use such products Refer to this Users Manual for proper use...

Страница 12: ......

Отзывы: