background image

7

Warranty

Schlage Lock Company warrants the product is free from defects in material and workmanship under normal use and service with proper maintenance for two 
years from the date of factory shipment. Schlage Lock Company assumes no responsibility for products damaged by improper handling or installation. This 
warranty is limited to the repair or replacement of the defective unit.

There are no expressed warranties other than set forth herein. Schlage Lock Company does not make, nor intends, nor does it authorize any agent or 
representative to make any other warranties, or implied warranties, and expressly excludes and disclaims all implied warranties of merchantability or fitness for a 
particular purpose.

Returned units are repaired or replaced from a stock of reconditioned units. Returns must be accompanied by a return authorization number (RMA) obtained 
from customer service, and prepaid postage and insurance.

Liability

The card readers should only be used to control exits from areas where an alternative method for exit is available. This product is not intended for, nor is rated 
for operation in life-critical control applications. Schlage Lock Company is not liable under any circumstances for loss or damage caused by or partially caused 
by the misapplication or malfunction of the product. Schlage Lock Company’s liability does not extend beyond the purchase price of the product.

Содержание Schlage SMR-10

Страница 1: ...on box is used a wall plate optional may be used to cover the junction box The reader is then secured to the mounting bracket using a screw Refer to figures for reader dimensions and typical junction...

Страница 2: ...not use sealant to seal reader case to the wall Doing so will trap water in the reader and may cause damage to the reader TTL Interface The TTL interface has the standard 5 wire interface widely used...

Страница 3: ...zero bits otherwise sends data as is Tamper monitor enabled 3 Mag stripe data output with zero trim reverse read correction and error filter enabled using CLOCK DATA signaling Tamper monitor disabled...

Страница 4: ...ill flash Otherwise the red LED will flash and the buzzer will sound two short beeps to indicate an error The LED input can be used to verify the LED function and the buzzer input for the buzzer funct...

Страница 5: ...mension 1 95 50mm W x 1 30 33mm H x 5 50 140mm L Weight 10 oz 284 g nominal Material Case Die cast aluminum gray powder coat standard Mounting stainless steel Wall plate 18 CRS gray powder coat standa...

Страница 6: ...l Wall Plate part WP10 6 30 160 3 30 84 1 38 35 1 23 31 1 40 36 4 00 102 2X 0 18 4 5 2 75 70 Fitting Rigid Conduit to Junction Box WALL OPENING FOR J BOX Rigid Conduit 1 Gang Box WALL STUD Wall Openin...

Страница 7: ...and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returned units are repaired or replaced from a stock of reconditioned units Returns m...

Страница 8: ...Allegion 2017 Printed in U S A 23884539 Rev 08 17 b...

Отзывы: