background image

65

Table 5 – Signal input/output parts Port

Phenomenon

Basic EMC standard 

Electrical fast 

transients/burst 

IEC 61000-4-4 

Conducted 

disturbances 

induced by RF 

fields 

IEC 61000-4-6 

Immunity test levels 

Professional healthcare facility environment 

±1 kV 

100kHz repetition frequency 

3V, 0.15MHz-80MHz 

6V in ISM bands between 0.15MHz and 80MHz 80%AM at 1kHz 

Содержание ASW-203

Страница 1: ...User Manual ASW 203 1 Copyright 2022 All Star Wheelchairs...

Страница 2: ...2 Table of Contents Introduction 3 Safety 5 Your Electric Wheelchair 10 Assembly Disassembly 16 Controller operation 20 Comfort Adjustments 29 Batteries and Charging 35 Care and Maintenance 46...

Страница 3: ...your power chair for the rst time You must also read all instructions warnings and notes contained in any supplemental instructional booklets for the controller that accompanied your power chair befor...

Страница 4: ...r preserve the safe use of this product Shipping and Delivery Before using your power chair make sure your delivery is complete as some components may be individually packaged If you do not receive a...

Страница 5: ...re more warnings identi ed and explained in the Consumer Safety Guide that is included with your power chair Please become familiar with all the warnings and safety information found in the Consumer S...

Страница 6: ...6 Unlocked and in freewheel mode Class II Equipment Power Chair information label Manufacturer Do not remove the anti tip wheels Not to be used as a motor vehicle seat...

Страница 7: ...making such a decision and his her healthcare professional i e medical doctor physical therapist etc The contents of this manual are based on the expectation that a mobility device expert has properl...

Страница 8: ...you become accustomed to operating your power chair safely Pre Ride Safety Check Get to know the feel of your power chair and its capabilities We recommend that you perform a safety check before each...

Страница 9: ...problem contact your authorized Provider for assistance Safety Warnings Do not use on inclines 6 Do not charging while operating Unplugging charger before operation It is folding wheelchair please co...

Страница 10: ...stability of speed and direction It is intended used in Home healthcare environment or on gentle surfaces Identi cation Key 1 Seat Backrest 7 Motor 13 Storage Compartment 2 Armrest 8 Caster Wheel 14...

Страница 11: ...11 Figure 1 ASW 203 Figure 2 Figure 3 2 1 14 4 3 8 6 14 15 13 11 5 3 12 10 7...

Страница 12: ...secured to the assembly and not allowed to drag on the oor Battery Box Charger Port This enables you to charge the battery when the battery box is removed from the power base See Batteries and Chargin...

Страница 13: ...eewheel mode when on a level surface WARNING It is important to remember that when your power chair is in freewheel mode the braking system is disengaged WARNING Do not disengage the drive motors whil...

Страница 14: ...l freewheel levers down to disengage the drive motors free mode 3 Pull up the manual freewheel levers inward to engage the drive motors drive mode D Drive Mode Drive Engaged N Freewheel Mode Drive Dis...

Страница 15: ...partments Your power electric wheelchair is equipped with one storage compartments It is located on the seat backrest WARNING The storage compartment on the rear of the seat backrest is for small pers...

Страница 16: ...parts from its packaging 2 Place one hand on top of the seat backrest and push it downward 3 Install the controller to the right or left hand armrest of the driver 4 Insert the controller into the arm...

Страница 17: ...n reinstallation that your power chair can fold and unfold without creating harness pinch points 5 Sit on the seat and lie down or press the top of the seat backrest downward Con rm the folding and lo...

Страница 18: ...d for easy transportation and storage To fold the power chair 1 Pull the folding and locking mechanism to make the wheelchair unlock 2 Fold the foot platform upwards toward the seat of the power chair...

Страница 19: ...seat backrest upward 2 Sit on the seat and lie down or press the top of the seat backrest downward 3 Con rm the folding and locking Mechanism is locked WARNING To avoid injury ensure the seat backrest...

Страница 20: ...the controller When operating the wheelchair ensure that the control system is safe and reliable Operating environment Do not keep the control system and its components in a humid environment for long...

Страница 21: ...meter electricity indicator Switch key and battery meter Power switch button is the control form of power supply to control system Press the power switch button once to get the power on of the contro...

Страница 22: ...oystick is 0 1N The joystick is pushed forward and the electric wheelchair is pushed forward The joystick moves backward the electric wheelchair moves backward and there is a sound warning to remind t...

Страница 23: ...ased and the safety circuit of the control system has started to operate to prevent the control system from moving the wheelchair and causing system error That is M7084 has detected that there is a pr...

Страница 24: ...ease check whether the motor wire connection at the side is normal Three lights on It indicates that the right brake of the control system is faulty Check whether the wiring and brake handle are in pl...

Страница 25: ...relay burned out If the wheelchair is powered on normally but the electric wheelchair cannot be moved by pushing the joystick and the control system does not alarm please check whether the motor conne...

Страница 26: ...or failure 5 Left brake 6 Over current 7 Joystick 8 Controller failure 9 Battery failure For example It means that the frequency of the rst two guiding sounds is fast and the frequency of the last fou...

Страница 27: ...ck PCB and wipe the copper foil on the PCB with alcohol The controller turns on the power controls the alarm and detects whether the brake is plugged in Check whether the wire of the brake is in good...

Страница 28: ...ectric wheelchair is not enough no force Check whether the battery power is stable If the battery power drops quickly please use it after charging The suction force of the brake is not enough and the...

Страница 29: ...ic majority of users Your authorized Provider has evaluated your power chair and made any necessary adjustments to suit your speci c requirements Do not change your seating con guration without rst co...

Страница 30: ...e the controller position Turn off the power to the controller Open or Cut the wire ties securing the controller harness to the frame Unhook the controller harness from the wire ties Reinstall them on...

Страница 31: ...r and latch the quick release handle Flip up the armrest Use wire ties to secure the controller harness to the frame Ensure that the armrest can freely be raised and lowered without any tension on the...

Страница 32: ...t is not designed for use as a restraining device WARNING The positioning belt is not designed for use as a seat belt in a motor vehicle Nor is your power chair suitable for use as a seat in any vehic...

Страница 33: ...fort To release the positioning belt 1 Press the push button mechanism on the plastic housing MANDATORY Make sure the positioning belt is properly secured to the power chair and is adjusted for operat...

Страница 34: ...34 Armrest 1 Press the button on the underside of the armrests to loosen them...

Страница 35: ...e unsafe for use in power chairs Batteries and Charging MANDATORY Battery posts terminals and related accessories may contain lead and lead compounds Wear goggles and gloves when handling batteries an...

Страница 36: ...e the battery is charging We recommends that you do not charge the battery while the power chair is occupied MANDATORY Read the battery charging instructions in this manual and in the manual supplied...

Страница 37: ...ontact and do not place on surfaces that may be affected by the heat WARNING If the battery charger is equipped with cooling slots then do not attempt to insert objects through these slots WARNING If...

Страница 38: ...ard charger programming socket of the controller 4 Plug the off board charger into the electrical outlet 5 When the battery is fully charged unplug the off board charger from the electrical outlet and...

Страница 39: ...into the battery box charger port Plug the off board charger into the electrical outlet NOTE off board chargers contain two lights The red light indicates that power to the off board charger is on The...

Страница 40: ...removing the battery box Table 1 Battery Condition Meter Codes LED Battery Percentage 5 55 100 battery remaining 4 35 55 battery remaining 3 20 34 battery remaining 2 12 19 battery remaining 1 12 bat...

Страница 41: ...arly at zero This is how the charger maintains a charge but does not overcharge the battery Can I use a different battery charger You should use the charger supplied with the power chair It is the saf...

Страница 42: ...ttery condition meter codes Infrequent Use If you use your power chair infrequently once a week or less you should charge the battery at least once per week for 12 to 14 hours NOTE Keep your battery f...

Страница 43: ...e information regarding the battery used with your power chair WARNING Corrosive chemicals contained in batteries Use only Lithium Ion batteries to reduce the risk of leakage or explosive conditions W...

Страница 44: ...emperature More importantly it will take a few charging cycles a full drain then a full recharge to establish the critical chemical balance that is essential to the battery s peak performance and long...

Страница 45: ...Avoid temperature extremes such as freezing and excessively hot conditions and never attempt to charge a frozen battery A cold or frozen battery should be warmed for several days prior to recharging W...

Страница 46: ...your power chair s care or operation contact an authorized Provider WARNING Do not service the power chair when the seat is occupied Your power chair like most electrical equipment is susceptible to...

Страница 47: ...ovider Power chairs that are frequently exposed to sources of water such as incontinence should be inspected often for corrosion and electronic components may need to be replaced frequently Temperatur...

Страница 48: ...the psi bar kPa air pressure rating indicated on each tire WARNING Make sure pneumatic tires are in ated to the psi bar kPa air pressure rating indicated on each tire Do not underin ate or overin ate...

Страница 49: ...controller turned off check the joystick Make sure it is not bent or damaged and that it returns to the neutral position when you release it Check the rubber boot around the base of the controller fo...

Страница 50: ...uld be carried out on a level surface with at least 3 feet 1 meter of clearance around your power chair To check the brakes Turn on the controller and turn down the speed level on your power chair Aft...

Страница 51: ...the bearings replaced See an authorized Provider for repair Check the entire power chair for loose hardware and changes in the function or performance of the power chair See your authorized Provider...

Страница 52: ...ended that you charge the battery periodically throughout periods of prolonged storage to ensure proper performance You may wish to place several boards under the frame of your power chair to raise it...

Страница 53: ...f the disinfectant and or cleaning agent before applying it to your product Failure to comply may result in skin irritation or premature deterioration of upholstery and or power chair nishes Cushion C...

Страница 54: ...e cushions to air dry WARNING Never submerge the cushions in water Doing so may cause damage to the cushions WARNING Do not attempt to put cushions in a dryer This may cause shrinking Once the cushion...

Страница 55: ...orized Provider WARNING The wheels on your power chair should only be serviced by an authorized Provider or a quali ed technician WARNING Be sure that the power to the controller is turned off and the...

Страница 56: ...new wheel back onto the shaft Make sure that the key is in the axle slot In ate the pneumatic tire to the psi bar kPa air pressure rating indicated on each tire Reinstall the drive wheel nut and washe...

Страница 57: ...er handling WARNING The battery in your power chair should only be serviced or replaced by an authorized Provider or a quali ed technician WARNING Do not replace the battery when the seat is occupied...

Страница 58: ...ollowing symptoms could indicate a serious problem with your power chair If necessary contact an authorized Provider When calling have the model number serial number nature of the problem and the erro...

Страница 59: ...s Make sure they are tight Check the circuit breaker Reset it if necessary Check the battery connections If the above conditions prove normal you can load test the battery with a battery load tester T...

Страница 60: ...y of speed and direction It is intended used in Home healthcare environment WARNING Use of this electric wheelchair adjacent to or stacked with other equipment should be avoided because it could resul...

Страница 61: ...5 km from AM FM or TV broadcast antennas before using this equipment it should be observed to verify that it is operating normally to assure that the equipment remains safe with regard to electromagn...

Страница 62: ...static Discharge IEC 61000 4 2 8 kV contact 2kV 4kV 8kV 15kV air Radiated RF EM eld IEC 61000 4 3 10V m 80MHz 2 7GHz 1kHz 80 AM 20V m 26MHz 2 5GHz 1kHz 80 AM Proximity elds from RF wireless IEC 61000...

Страница 63: ...5240 5500 5785 Band MHz 380 390 430 470 704 787 800 960 1700 1990 2400 2570 5100 5800 Pulse modulation 217Hz 9V m Pulse modulation 18Hz 28V m Pulse modulation 217Hz 28V m Immunity test levels Home hea...

Страница 64: ...EC 61000 4 6 Voltage dips IEC 61000 4 11 Voltage interruptions IEC 61000 4 11 Immunity test levels Home healthcare environment 2 kV 100kHz repetition frequency 0 5 kV 1 kV 3V 0 15MHz 80MHz 6V in ISM a...

Страница 65: ...lectrical fast transients burst IEC 61000 4 4 Conducted disturbances induced by RF elds IEC 61000 4 6 Immunity test levels Professional healthcare facility environment 1 kV 100kHz repetition frequency...

Отзывы: