background image

1

PowerPallet

Setup and Maintenance

Updated:  09/15/2012

ALL Power Labs, Inc

Berkeley, CA

[email protected]

[email protected]

Содержание PowerPallet

Страница 1: ...1 PowerPallet Setup and Maintenance Updated 09 15 2012 ALL Power Labs Inc Berkeley CA sales allpowerlabs org support allpowerlabs org...

Страница 2: ...reparation b Pressure Testing IV Safety and Safety Features A Carbon Monoxide Safety B Safety around Combustible Gases C System Safety D Environmental Precautions V Service and Maintenance of System C...

Страница 3: ...edule for the first of several run cycles This will ensure the system as a whole runs in a safe manner at its highest efficiency with the lowest possible emissions and have a longer total life overall...

Страница 4: ...stool box knife and scissors Engine oil Engine coolant 12v DC car battery car battery charger if needed hex wrench size bucket voltmeter small 12v air compressor or air pump fine sifting screen and 1...

Страница 5: ...om of the Gas Filter to the inlet of the Gas Blowers For the single Air Blower attach the flange to the shorter inlet of the Flare Stack Make sure the orange silicone check gasket is seated properly i...

Страница 6: ...ositive red and negative black leads provided on the PowerPallet c Wiring the Generator If you specified the voltage and frequency at the time of order the unit may have been configured to you specifi...

Страница 7: ...urface An area 5 feet surrounding the PowerPallet should be free of leaves or combustible materials Well ventilated area is needed during maintenance CO exposure is very rare during operation however...

Страница 8: ...particle size filled to 10 from the top of the filter prepared foam filter disk 65dpi larger pore size prepared foam filter disk 45dpi smaller pore size second filter grate The media should fill the g...

Страница 9: ...sts on the system to detect for leaks before all of our shipments seals may become compromised during shipping or over many hours of running Because the system operates under a vacuum gaps in the syst...

Страница 10: ...inlet open while the system is running especially the engine to prevent further increasing the vacuum past the system limits D Environmental Precautions Periodically the condensate traps of the cyclo...

Страница 11: ...hrs 10cycles 300hr 50cycles 1000hrs 100 cycles GEK Inspect Gaskets X Purge Char from Reactor X Check Clean Cyclone X Check Empty Cyclone Condensate Jar X Check Change Gas Filter bulk media X Check Cle...

Страница 12: ...h temp mortar or the silicone RTV Feedstock Hopper As the hopper lid may be used often make sure this hopper lid maintains a good seal Drying Bucket The Drying Bucket baffles help increase the heat ex...

Страница 13: ...les Because the highest temperatures are experienced at the tip of the air nozzles of any gasifier system these will need to be checked for any thermal damage Check the tip of the Nozzles to make sure...

Страница 14: ...have occurred over time If build up does occur ie wood tar or oxidation clean with isopropyl alcohol Intake Valves If tar is allowed into the engine build up may occur on the intake valves The first i...