Wire (EU)
Wire (US)
Pin
Marking
Brown Black Live
L
Blue White
Neutral
N
Yellow Green GND
2.2 Connection between fixtures
The fixture is equipped both 3 and 5-PIN XLR sockets for DMX input and output. Only use a
shielded twisted pair cable designed for 3 or 5-PIN XLR plugs and connectors in order to
connect the controller with fixture or one fixture with another.
i.
DMX Serial Data Link
If you are using the standard DMX controller, you can connect the DMX output of the
controller directly with the DMX input of the first fixture in the DMX-chain. Connect the DMX
output of first fixture in the chain with DMX input of next fixture. Always connect one output
with input of next fixture until all fixtures are connected.
____________________________________________________________________________
Page 5 of 13 Tracpod 84 User Manual
ii.
Master/Slave Data Link