background image

DJ196  INSTRUCTION  MANUAL

                                                                       

1.  INNOVATIVE AND NEW FEATURES

.  Comes equipped  39 CTCSS Tone Squelch function.

.  Comes equipped 104DCS Digital code squelch function.

.   TOT(Time Out Timer) can be set to a Duty Cycle most accommodating to the user’s

requirements.

.  Alphanumeric channel name function.

.  Tone burst function

1750,2100,1000,1450Hz

.  Nine  Autodial memories easily accessed from the DTMF keypad with redial function.

.  Direct frequency entry from DTMF function.

.   Burglary Alarm Function

.  Mosquito Repel sound function.

2.  SPECIFICATIONS

 GENERAL

  

Frequency coverage

T: TX 144-147.995MHz

  

RX 135-173.995MHz

        

      E: TX 144-145.995MHz

  RX 144-145.995MHz

           

  

        

      TA2: TX 150-173.995MHz

  

RX 135-173.995MHz

        

       

  

Mode      

  

               F3E

(FM)

  

Channel steps

  

            5,10,12.5,15,20,25,& 30kHz

  

Memory channels

            40 channels

1CALL channel

    Antenna connector            BNC(50ohm unbalanced

    Frequency stability

        +/-5 ppm

    Microphone input impedance   2Kohm  nominal

    Power supply requirement

   6.0 - 16.0 V DC (negative ground)

  

Current drain (at 13.8 V DC)

1.2 A(typical)

Transmit high at  5W

 

        

                 200 mA(typical)

Receive at 280mW

        

                  50 mA(typical)

standby

    Usable temperature range

  

  -10 - +60 deg.

    Dimensions

  

                56(

W)*

124(H)

 40(D)mm (with EBP-48N)

  

  (Projections not included)

                           

    Weight 

           

Approx.375

g(

with EBP-48N

    DTMF

  

                    16 Buttons Keypad

    Subaudible Tone(CTCSS) encoder/decoder installed(39tones)

    Subaudible Tone (DCS) encoder/decoder installed(104codes)

  TRANSMITTER

  

Output power

         

 Approx.  5 W

EBP-48N installed

        

             Approx.  5 W

13.8 V DC

         Approx.  0.8 W

(LOW)

  

Modulation system

   

  Variable reactance frequency modulation

  

Spurious emissions

  

   Less than  -60dB

  

Max.frequency deviation

+/-5Hz

  

Содержание DJ-196

Страница 1: ...95MHz Mode F3E FM Channel steps 5 10 12 5 15 20 25 30kHz Memory channels 40 channels 1CALL channel Antenna connector BNC 50ohm unbalanced Frequency stability 5 ppm Microphone input impedance 2Kohm nominal Power supply requirement 6 0 16 0 V DC negative ground Current drain at 13 8 V DC 1 2 A typical Transmit high at 5W 200 mA typical Receive at 280mW 50 mA typical standby Usable temperature range ...

Страница 2: ...sion EDC 94 230V AC Wall charger E version Flexible rubber helical antenna Belt clip Hand strap Instruction Manual Accessories may differ depending on the version you bought Optional Accessories EBP 48N 9 6V DC 700mAh Ni Cd battery EDC 36 Mobile Cigarette lighter adapter with active noise filter EDC 37 External DC supply cable EDC 88 Rapid charger EDC 93 120V Wall charger EDC 94 230V Wall charger ...

Страница 3: ...5 19 Clock Shift Function 6 Operation 2 Applications 6 1 Selective Calling 6 2 Tone Encoder and Tone Squelch Function 6 3 Tone Encoder Frequency Tone Decoder Frequency Programming 6 4 DCS Digital CodeSquelch Function 6 5 Manual DTMF Transmitting 6 6 Auto Dialer Memory Setting 6 7 Auto Dialer Function 6 8 Redial 6 9 DTMF Time Setting 6 10 Alphanumeric Function 6 11 TOT Time Out Timer Function 6 12 ...

Страница 4: ...nal mode When no operation is continued for 5 seconds the setting is completed automatically Then the LCD will return to the ordinal mode Operation The squelch will be opened with the strong signal when the high value is set 5 3 Receiving 1 Turn the power SW ON 2 Press the VOL key to increase the volume Rotate the dial to set to the proper volume 3 Press and hold the SQL key and rotate the dial un...

Страница 5: ...kHz Enter up to 10kHz digit 12 5kHz 10kHz Enter 10kHz digit and 1kHz digit 0 00 0 1 12 5 2 25 0 3 37 5 4 invalid 5 50 0 6 62 5 7 75 0 8 87 5 9 invalid 15 0kHz 1kHz Enter up to 1kHz digit 25kHz 10kHz Enter 10kHz digit and 1kHz digit is determined 0 00 0 2 25 0 5 50 0 7 75 0 Others are invalid 30kHz 10kHz Enter 10kHz digit and 1kHz digit is determined 5 6 Channel Step 1 Press and hold the F key then...

Страница 6: ...essing 2 STEP key while holding the FUNC key 5 8 Memory Channel Operation This unit is provided with 40 memory channels 0 9 CH and one call channel C The memory can not be increased 1 Calling of memory channel 1 Press V M key and M will appear on the LCD indicating the unit enters the memory mode M icon flashes to show the CH s memory has not been programmed and the VFO frequency is displayed 2 Ro...

Страница 7: ... the LCD and the unit enters the CALL mode In CALL mode the frequency and memory channel number can not be changed by dialing The offset setting and tone setting can be changed and operated temporarily 2 Press the CALL key again to return to VFO mode or memory mode Also pressing the V M key causes to return to the previous VFO mode or memory mode 3 Scanning can not be done in the CALL mode 2 Chang...

Страница 8: ...e press and hold the function key then press C SKIP while F icon is ON the selecting memory channel is programmed to the skip channel The skip channel is determined at this point without memory programming The skip channel is released with the same operation The 10MHz decimal point of the memory channel will appear when the skip channel is programmed to the channel 5 11 Output Power Switching The ...

Страница 9: ...e battery save function is set to OFF automatically while scanning When no signal and no operation are continued for 5 seconds the battery save function will be resumed automatically When a signal is received or an operation is performed battery save function is released temporarily 5 16 Lamp Function Press and hold the F key then press MONI key while F icon is ON The LCD backlight will be turned ...

Страница 10: ...ss 4 TSQL key while F icon is ON the current mode and tone frequency are displayed Each time 4 TSQ key is pressed the mode is switched as follows T T SQ 88 5 88 5 TCS OF Only T appears indicating the encoder function setting only is allowed T SQ appears indicating encoder decoder function setting While the tone frequency is displayed the lamp function and MONI key are available Press any key excep...

Страница 11: ... function and MONI key are available while indicating the code on the LCD Press any key except for FUNC and MONI keys to complete the setting The LCD returns to the ordinal mode with DCS indication DCS code changing When you change the DCS code 1 Set the DCS code in the DCS code setting mode DCS icon is ON 2 Change the DCS code with dialing then the setting is completed 3 When the memory is progra...

Страница 12: ... be output from the speaker automatically In this case the code is not sent If nothing is stored in the memory a beep tone sounds indicating that the operation is invalid when you press a key of 1 9 Operation in transmitting mode 1 Press F key in the transmitting mode DIAL appears on the LCD 2 Press a key of 19 the dialer memory that is accordant with the key No max 16 digits will be transmit auto...

Страница 13: ... storing the stored letters will be erased 9 Press the PTT key to complete the operation Operation of alphanumeric function 1 When the unit enters the memory mode if the channel is programmed alphanumeric function the frequency display part will be showed with the stored alphanumeric letters The CH number will be displayed as it was Press F key and the frequency will appear for 5 seconds on the LC...

Страница 14: ...pears 2 The tone frequencies match and the squelch is opened while using the tone squelch 3 The codes match and the squelch is opened while using DCS 7 Operation 3 Others 7 1 Cable Clone With an interface cable the entire memory channel data of one transceiver can be transferred and copied to another transceiver Connection As shown in the figure connect the external speaker jacks of two transceive...

Страница 15: ...ker is ON Set to EXP ON in the set mode When receiving The tone and code should match when the TSQ DCS is set DC5V 5mA max is output from the center terminal of MIC stereo jack Set to EXP OF in the set mode to cancel this function The optional VOX MIC etc EME 12 EME 13 EME 15 can not be used at EXP ON 7 4 MPS Mosquito Repel Sound Function This function generates the supersonic that repels mosquito...

Страница 16: ... 2 Rotate the dial and the display toggles as shown below Then the tone burst frequency will be changed Downward Upward 1750 2100 1000 1450 No 5 Clock Shift Setting 1 SFT OF appears on the LCD 2 Rotate the dial and the display toggles as shown below Then the setting of the CLOCK will be changed Downward Upward SFT OF SFT ON No 6 Busy Channel Lock Out Setting 1 BCL OF appears on the LCD 2 Rotate th...

Страница 17: ...rd Upward DP 60 DP 80 DP 160 DP 200 No 10 The First Digit Burst Time of DTMF 1 DB 60 appears on the LCD 2 Rotate the dial and the display toggles as shown below Then the first digit of DTMF burst time will be changed 3 shows the current the first digit of DTMF burst time The initial setting is 60 msec DB 60 appears on the LCD 4 Rotate the dial to change the first digit of DTMF burst time Downward ...

Страница 18: ...MHz CALL frequency 145 00MHz 145 00MHz 145 00MHz 445 00MHz 433 00MHz Memory channel a blank a blank a blank a blank a blank SHIFT setting none none none none none SHIFT frequency 600kHz 600kHz 600kHz 5MHz 7 6MHz Channel step 5kHz 12 5kHz 5kHz 5KHz 12 5KHz Press and hold the F key the LCD s all segments are turned ON When you release the F key the reset will be performed Press and hold the F key th...