2
w w w . a l i e n p r o . c o m . m x
3
w w w . a l i e n p r o . c o m . m x
Attention
2. Please do not see the laser beam directly to avoid and damage.
3. Before connect or disconnect the power, please adjust the luminace of the laser diode to the least
to avoid any damage to the laser diode.
4. This unit should be keep dry, do not use in the rain and dusty environment. It can be use in the
outdoor with the water - proofcover protector.
5. Set the light immobility and try to avoid strong shake or hit.
6. Prevent dust into the equipment to avoid problems.
7. Please keep that there´s no other equipment or decorating materials obstructed the exhaust fan
and the vent - pipe when the equipment was working.
8. Before connect power, check the plug is immobility or not, power line should be connect well.
9. Please do not open or close the equipment frequently that´s to avoid any affect to the life span of
the laser diode, any try the best to avoid the long time working.
10. Due to the characteristic of the laser diode, after for ours working, it should be close at least 25
minutes until the laser diode cooling then work again.
11. Don´t touch the light or draw the power line when your hand was wet. And do not pull the
electronic power line.
12. Maintain the distance at least 3M above from the equipment to the object.
13. This equipment does not have any parts can repair for the users, please do not open the equip-
ment.
14. When the laser diode became dim or damge please contact the dealer timely.
15. When you want to retransfer the products, you´d better use the original package to shockproof.
Function Instructions
Channel Instruction
1. When dip switch No. 10 is set to the “ON” position, the unit works in auto mode.
2. When all dip switches are set to the “OFF” position, the unit works in sound - active mode.
3. Auto-play (Master - Slave synchronization): when master laser dip switch setting to No. 10, the
light will run the settled program automatically, meanwhile, it will have DMX512 signal´s output. Just
one ligth could be settled to be master. Setting salve: you should put dip switch No. 1 in “on”.
5. Address code function mode setting
Maintenance
Maintenance should be performed every 15 - day period, by using a sponge wich is dipped woth
alcohol, rather than wet cloth or other chemical liquid, to clean the mirror. Always disconnect from
the mains when the device is not in use or before cleaning it.
Warning
Power must be disconnected before maintenance or repair. Do not look at the light source direct-
ly. To prevent or reduce the risk of electrical shock or fire, do not expose this unit to high
temperature/rain or moisture.
Note
Don´t separate laser machine from laser power and repair them by yourself, otherwise no good
repair service will be supplied.
Mode
Binary code
(
ON
)
1 DMX-512 mode
、
Slave mode
1-9:Setting address code
10:OFF
2 Sound active mode
、
Master mode 1-10:OFF
3 Auto play mode
、
Master mode 1-9:OFF
10:ON
4 Square test pattern
9
、
10:ON
1
、
2
、
3
、
4
、
5
、
6
、
7
、
8:OFF
5 Dot text pattern
8
、
9
、
10:ON
1
、
2
、
3
、
4
、
5
、
6
、
7:OFF
Channel
Value
Description
CH1
0
~
64
Close light
64
~
127
Auto-play
128-191
Sound active
192-255
Patterns control
CH2
0
~
255
Choose patterns
CH3
0~63
Choose patterns size
64~127
From small to large,speed up rate
128-191
From large to small,speed up rate
192-255
Large – small – large, speed up rate
CH4
0~127
Choose rotation angle
128~191
Auto clockwise rotation, speed up rate
192~255
Auto anti-clockwise rotation, speed up rate
CH5
0~127
Choose horizontal position
128~255
Horizontal move,speed up rate
CH6
0~127
Choose Vertical position
128~255
Vertical move,speed up rate
CH7
0~127
Choose horizontal roll position
128~255
Horizontal roll ,speed up rate
CH8
0~127
Choose Vertical roll position
128~255
Vertical roll,speed up rate