5
www.observint.com
© 2017 Observint Technologies. All rights reserved.
General
Operating Conditions
-40 °F ~ 140 °F (-40 °C ~ 60 °C), Humidity 90% or less (non-condensing)
Power Supply
12 Vdc ± 25%
Power Consumption
Max. 3W
Protection Level
IP67, IK10
Material
Metal
IR Range
Up to 65 ft (20 m)
Communication
Up the coax
Dimensions
φ4.4” × 3.2” (φ111 mm × 82.4 mm)
Weight
Approx. 0.77 lb (350 g)
Cleaning Instructions
•
Dust or grease on the dome cover will cause IR reflection. Do not remove the dome cover film until the
installation is finished. If there is dust or grease on the dome cover, clean the dome cover with clean
soft cloth and isopropyl alcohol.
•
Make sure that there is no reflective surface too close to the camera lens. The IR light from the camera
may reflect back into the lens causing reflection.
•
The foam ring around the lens must be seated flush against the inner surface of the bubble to isolate
the lens from the IR LEDS. Fasten the dome cover to camera body so that the foam ring and the dome
cover are attached seamlessly.
Clean the camera dome with an approved glass cleaning solution and a lint free cloth.
•
Dust can be removed from the unit by wiping it with a soft damp cloth. To remove stains, gently rub
the surface with a soft cloth moistened with a mild detergent solution, then rinse and dry it with a
soft cloth.
•
Remove all foreign particles, such as plastic or rubber materials, attached to the camera housing.
These may cause damage to the surface over time.
CAUTION
Do not use benzene, thinner or other chemical products on the camera assembly; these may
dissolve the paint and promote damage of the surfaces. Before using any chemical product,
carefully follow the accompanying instructions.
Troubleshooting
Problem
Possible Cause
Nothing appears on the screen
- Check the power connection.
- Check the video signal cable connection to the monitor.
The video image is dim or not clear.
- If the camera lens is dirty, clean it with a soft, clean cloth.
- Adjust the monitor controls, if necessary.
- If the camera is facing a very strong light, change the camera position.
- Adjust the lens focus.
The screen is dark.
- Adjust the contrast control of the monitor.
- If you have an intermediate device, set the impedance (75 Ω /Hi-Z)
properly, and check the cable connections.
The camera is not working properly and the
surface of the camera is hot.
- Verify that the camera is correctly connected to an appropriate regulated
power source.
The image on the monitor flickers
- Make sure that the camera isn’t facing direct sunlight or fluorescent light.
If necessary,change the camera position.