background image

5

www.observint.com

© 2018 Observint Technologies. All rights reserved.

 

D/N Threshold (Day to Night Threshold)

: Use the Day to Night Threshold to control the 

sensitivity of switching the day mode to the night mode. You can set the value from 1 (less 
sensitive) to 9 (more sensitive). 

 

N/D Threshold (Night to Day Threshold)

: Use the Night to Day Threshold to control the 

sensitivity of switching the night mode to the day mode. You can set the value from 1 (less 
sensitive) to 9 (more sensitive). 

Video Settings submenu

Move the cursor to Video Settings and click 

Iris+

 to enter the submenu. Use this submenu to adjust the 

Contrast, Sharpness, Saturation, 3D DNR, Mirror and Defog.

Contrast

: This feature enhances the difference in color and light between parts of an image. You can 

set the Contrast value from 1 to 10.

Sharpness

: Sharpness determines the amount of detail an imaging system can reproduce. You can 

set the Sharpness value from 1 to 10.

Saturation

: Use this option to change the color intensity. The value ranges from 1 to 10.

3D DNR (Digital Noise Reduction)

: Use the 3D DNR option to decrease video noise, especially 

when capturing moving images in low light conditions, to produce a better image quality. You can set 
the 3D DNR value from 1 to 10.

Mirror

: Off, H, V, and HV are selectable for mirror.

 

Off

: The mirror function is disabled. H: The image flips 180° horizontally. V: The image flips 180° 

vertically.

 

H, V, HV

: The image flips horizontally, vertically, or both horizontally and vertically.

Defog

: It is used in special environments such as the foggy or rainy weather, or in high illumination 

conditions, in which the image appears hazy. Enable the defog function can enhance the subtle 
details to display clear images.

Factory Default

Click 

Iris+

 to enter the submenu, and click 

OK

 to reset all the settings to the factory default. Click 

Cancel

 

to return to the menu without resetting the camera. 

Save & Exit

Move the cursor to 

Save & Exit

, and click 

Iris+

 to save the settings and exit the menu. If new settings are 

not saved, they remain in effect only until the camera is powered off or reset. 

Specifications 

Camera

Image Sensor

8 MP progressive scan CMOS sensor

Signal system

PAL / NTSC

Frame rate

PAL: 8 MP @ 12.5 fps, 5 MP @ 20 fps, 4 MP @ 25 fps, 1080p @ 25 fps  

NTSC: 8 MP @ 15 fps, 5 MP @ 20 fps, 4 MP @ 30 fps, 1080p @ 30 fps

Effective Pixels

3840 (H) × 2160 (V)

Min. illumination

Color: 0.003 Lux @ (F1.2, AGC ON),  

0 Lux with IR

Shutter Time

PAL: 1/12.5 s to 1/10,000 s  

NTSC: 1/15 s to 1/10,000 s 

Slow shutter

Max. 16 times

Lens

Motorized VF: 2.8 mm − 12 mm 2

Horizontal Field of View (FOV)

108.1° ~ 45.6°

Lens Mount

ф14

Day & Night

IR cut filter

Angle Adjustment

Pan: 0° ~ 355°; Tilt: 0° ~ 75°; Rotate: 0° ~ 355°

Synchronization

Internal Synchronization

WDR (Wide Dynamic Range)

120 dB

Menu

AGC

Supported

D/N Mode

Auto / Color / BW (Black and White)

White Balance

Auto / Manual / Natural

White balance

ON / OFF, 4 programmable privacy masks

BLC

Supported

3D-DNR (Digital Noise Reduction)

Level 1 to 10

Language

English

Functions

Contrast, Sharpness, Saturation, Mirror, Defog, HLC

Interface

TVI Video Output

1 HD-TVI output (75Ω / BNC)

CVBS Video Output

1 CVBS output (75Ω / BNC)

General

Operating Conditions

-40 °F ~ 140 °F (-40 °C ~ 60 °C ), Humidity 90% or less (non-condensing)

Power Supply

12 Vdc ± 25%  

24 Vac ± 25%

Power Consumption

Max. 10.5 W

Protection Level

IP67, IK10

Material

Metal

IR Range

260 ft max. (80 m max) 

Communication

Up the coax (HD-TVI output)

Dimensions

φ5.72” × 4.89” (φ145.2 mm × 124.1 mm) 

Weight

1.42 lb (645g)

Cleaning Instructions

• 

Dust or grease on the dome cover will cause IR reflection. Do not remove the dome cover film until the 
installation is finished. If there is dust or grease on the dome cover, clean the dome cover with clean 
soft cloth and isopropyl alcohol.

• 

Make sure that there is no reflective surface too close to the camera lens. The IR light from the camera 
may reflect back into the lens causing reflection.

• 

The foam ring around the lens must be seated flush against the inner surface of the bubble to isolate 
the lens from the IR LEDS. Fasten the dome cover to camera body so that the foam ring and the dome 
cover are attached seamlessly.

Clean the camera dome with an approved glass cleaning solution and a lint free cloth. 

• 

Dust can be removed from the unit by wiping it with a soft damp cloth. To remove stains, gently rub 
the surface with a soft cloth moistened with a mild detergent solution, then rinse and dry it with a 
soft cloth.

• 

Remove all foreign particles, such as plastic or rubber materials, attached to the camera housing. 
These may cause damage to the surface over time. 

CAUTION

Do not use benzene, thinner or other chemical products on the camera assembly; these may 
dissolve the paint and promote damage of the surfaces. Before using any chemical product, 
carefully follow the accompanying instructions.

Troubleshooting

Problem

Possible Cause

Nothing appears on the screen 

- Check the power connection. 

- Check the video signal cable connection to the monitor. 

The video image is dim or not clear.

- If the camera lens is dirty, clean it with a soft, clean cloth.

- Adjust the monitor controls, if necessary. 

- If the camera is facing a very strong light, change the camera position.

- Adjust the lens focus.

Содержание ALI-TP2118VR

Страница 1: ...cification of the products for the installation environment Make sure that the wall or the ceiling is strong enough to withstand 3 times the weight of the camera To avoid fire or shock hazard use only UL listed power supplies Verify that the power supply will provide the rated voltage and wattage for the camera See the Specifications section ALI TP2118VR 8MP HD TVI Vandalproof Outdoor Dome Camera ...

Страница 2: ...videocablemustattachtotheHD TVIcompatibleequipment IftheHD TVIvideocable willattachtoNTSCcompatibleequipment settheHD TVI CVBSswitchonthecameramodule appropriately Seethephotoonpage1 TheCVBSvideocableanattachtoanyequipmentcompatiblewithanNTSCsignal 7 Apply power to the camera Use caution to observe the DC power polarity shown in the photo on page 1 8 Verify that a video signal can be seen on your ...

Страница 3: ...igurationoptionsinthecamera See OSDDefinitions On screenDisplay OSD menus onpage4 Opening the OSD Menu through remote login to the HD TVI DVR To open the OSD menu during a remote login to the recorder 1 After logging into the HD TVI DVR open the camera in a single Live View window 2 In the PTZ control panel scroll down the Preset list to Preset95 click the entry to highlight it and then click the ...

Страница 4: ...htness level of the whole image and provides clear images with details When WDR is selected as the exposure mode you can set it as low medium high or off AGC Automatic Gain Control It optimizes the clarity of the image in poor light conditions The AGC level can be set as High Medium or Low Select Off to disable the AGC function NOTE The noise is amplified when the AGC is on Slow Shutter Slow Shutt...

Страница 5: ...s Slow shutter Max 16 times Lens Motorized VF 2 8 mm 12 mm 2 Horizontal Field of View FOV 108 1 45 6 Lens Mount ф14 Day Night IR cut filter Angle Adjustment Pan 0 355 Tilt 0 75 Rotate 0 355 Synchronization Internal Synchronization WDR Wide Dynamic Range 120 dB Menu AGC Supported D N Mode Auto Color BW Black and White White Balance Auto Manual Natural White balance ON OFF 4 programmable privacy mas...

Страница 6: ...evice set the impedance 75 Ω Hi Z properly and check the cable connections The camera is not working properly and the surface of the camera is hot Verify that the camera is correctly connected to an appropriate regulated power source The image on the monitor flickers Make sure that the camera isn t facing direct sunlight or fluorescent light If necessary change the camera position ...

Отзывы: