4. 

Double click on the Discovery Tool icon. The tool will automatically discover Alibi cameras and 
recorders installed on the network. 

In the example screen shown above, an ALI-NS1024VR camera was discovered. Notice that the IP 
address of the camera is 192.168.1.64 (default IP address). This camera, although configured for a 
subnet that is probably foreign to the network it is installed on, is still found by the tool. 

5. 

To change the network settings of the camera to be compatible with the subnet where it is installed, 
do the following: 

a. 

Click on the device to highlight it. Notice that the network parameters for the device populate 
the fields in the right frame. 

b. 

Modify the network settings to values compatible with the subnet where it is installed: 

 

»

If the 

IPv4 Address

 shown for the camera is 192.168.1.64 (default IP address) and the 

camera is new (un-configured) or was reset to its factory default state, the camera 

did not

 

find

 a DHCP server on the network. Modify the parameters in the right pane to values you 

prefer and are compatible with the network. An example is shown in the screen below. 

 

»

If the 

IPv4 Address

 shown for the camera is 

something other than

 192.168.1.64 (default 

IP address) 

and

 the camera is new or was reset to its factory default configuration, the 

camera 

did find

 a DHCP server on the network and acquired new network parameters that 

are compatible with the network. If necessary, change the parameters in the right pane to 
values that you prefer and are compatible with the network. An example is shown in the 
screen above.  

c. 

Enter the 

admin

 password for the camera in the 

Password

 field. The default 

admin

 user 

password for Alibi cameras is 

1111

d. 

Click the 

Modify

 button. The new IP address, port, and other settings will change and 

appear in the list with the device you modified. 

6. 

Close the Alibi Tools Utility by clicking the 

Close

 icon ( 

T

 ) in the upper-right corner of the screen.

Step 4.  Login to the camera

To access the camera from a computer on the LAN: 
1. 

Open your Microsoft Internet Explorer (IE) browser on your computer and enter the IP address of the 
camera in the URL field. In the example below, the IP address of the camera is 192.168.75.76.

© 2015 Observint Technologies. All rights reserved.