Lapcounter
ALGE-TIMING
– D-LC
4
E100930
2.2
Countup (00)
•
Display shows 00
•
Press the manual button shortly – display counts up one
•
Press the button for 3 seconds – display counts down one
•
Reset to zero by pressing the button for 5 seconds, if there is already zero on the display
it will change the counting mode to countdown
2.3
Countdown (99)
•
Display shows 99 an (first digit is blinking).
•
Set the desired start-value for the blinking digit
•
Press the button for 3 seconds, the next digit is now blinking
•
Repeat the 2 previous actions until you have adjusted all digits
•
The display shows the startvalue, no digit is blinking anymore
•
Pressing the button shortly increases the value by one
•
Pressing the button for 3 seconds counts up by one
•
Pressing the button for about 5 second resets to the start value. If the counter is already
at the start value, the counting mode is changed
3 Powerpack
The Lapcounter has an integrated Powerpack and charger which supplies power for about
15 hours in continous use.
To recharge the battery you have to supply the counter with mains for 14 hours.
ATTENTION!! If the value is not changed during 10 minutes the counter switches to
power save mode. Pressing the button once reactivates the counter in the previous
settings.