TROUBLESHOOTING TREE #3
IGNITER WILL NOT SPARK
CHECK
REIGNITER
BATTERY
BATTERY OK
BATTERY DEAD
REPLACE BATTERY
CHECK IF
ELECTRODE IS
CONTACTING HOOD
OR FURTHER THAN
1/8” (3 mm)
ADJUST AND
CHECK
OPERATION
OUT OF
POSITION
OK
CHECK ROCKER SWITCH BY
REMOVING LEADS AND
TOUCHING TOGETHER
WIPE
ELECTRODE
DRY OR LIGHT
MANUALLY
WITH TORCH
SPARK
ESTABLISHED
ROCKER
SWITCH IS
FAULTY -
REPLACE
CHECK IF
ELECTRODE
IS WET