Sporlan™ OMNI-Stat® Controller Settings 

 

 

 Values to be changed from default 

Model: 952892 - 120 VAC 

 

 

 

 

 

Code: 

Parameter: 

Value 

Default 

UOM 

Access 

W/O PS 

With PS 

PASSWORD 

PS 

Password 22 

22 

 

 

PROBE PARAMETERS 

/c 

Ambient probe calibration 

0 °F 

 

 

/2 

Measurement Stability 

4 ~ 

 

 

/4 

Probe to display (0=ambient / 1=product) 

 

 

/5 

Unit of Measure (0=°C / 1= °F) 

0 ~ 

 

 

REGULATION PARAMETERS 

rd 

Regulating Differential 

2 °F 

 

 

r1 

Minimum Allowed Temperature setting 

25 

-50 °F 

 

 

r2 

Maximum Allowed Temperature setting 

45 

60 °F 

 

 

r3 

Enable Def. alarm when max def. time reached 

 

 

r4 

Automatic variation of set point - 

NOT USED 

3 3 

 

 

COMPRESSOR PARAMETERS 

c0 

Delay compressor after power on 

Minutes 

 

 

c1 

Minimum time between 2 compressor runs 

Minutes 

 

 

c2 

Compressor shut down minimum time 

0 Minutes 

 

 

c3 

Compressor Operation minimum time 

Minutes 

 

 

c4 

Compressor Safety (0=OFF / 100=ON) 

100 

0 ~ 

 

 

cc 

Continuous Cycle Duration 

Hours 

 

 

c6 

Alarm Delay after continuous cycle 

Hours 

 

 

DEFROST PARAMETERS 

d0 

Defrost type (0=heater / 1=Hot Gas / 2=timed 
heater / 3=timed HG) 

 

 

dI 

Defrost interval 

8 Hours 

 

 

dt 

Defrost Ends Temperature 

50 

4 °F 

 

 

dP 

Max. Defrost Duration 

30 

30 Minutes 

 

 

d4 

Defrost after power on (0= NO / 1= YES) 

  

 

d5 

Defrost delay after power on 

Minutes 

  

 

d6 

Block Display during Defrost (0= NO / 1= YES) 

  

 

dd 

Dripping time after defrost 

Minutes 

 

 

d8 

Alarm delay after defrost 

Hours 

 

 

d9 

Defrost priority over minimum compressor time 
(0= NO / 1= YES) 

 

 

d/ 

Defrost probe -  display temperature 

 

 

dc 

Time base for dI and dP (0= hrs / 1= minutes) 

  

 

ALARM PARAMETERS 

A0 

Alarm and Fans Differential Temp 

°F 

  

 

AL 

Low temperature alarm (0= OFF) 

°F 

 

 

AH 

Hight temperature alarm (0=OFF) 

°F 

 

 

Ad 

Alarm Temperature delay 

Minutes 

  

 

A7 

Alarm imput detection delay 

Minutes 

  

 

OTHER PARAMETERS 

H0 

Serial Address (communications) 

  

 

H1 

Alarm Relay Operation (0=Alarm w/relay ON - 
1=Alarm w/ relay OFF) 

  

 

H2 

0= Disable Buttons / 1=Enable Buttons 

  

 

H5 

Identification for Programming 

 

 

External Programming 

 

 

Содержание ARFG-42

Страница 1: ......

Страница 2: ...CONTROLLER LOCATION AND MAIN POWER SWITCH COVER REMOVED POWER J BOX CONDENSER FAN TXV LOCATION FILTER DRIER COMPRESSOR EVAPORATOR ASSEMBLY EVAPORATOR FAN REMOVED FOR REPLACE MENT REMOVE PLATE AND BRACKET FOR FAN MOTOR REPLACEMENT ...

Страница 3: ...on the same circuit as the compressor They both operate at the same time Verify that the condenser fan receives power and the fan blades rotate freely Verify if there is debris in the blades that prevents it from starting ie leaves paper grass clippings etc VENTILATION IN THE UNIT Does the unit have enough ventilation on the back to allow for free cool air to reach the condenser Many installations...

Страница 4: ...ir does not hold temperature products do If there is not product in the re frigerator the unit will turn ON and OFF several times per hour If the unit is fully stocked the run time will be extended but also the off time allowing the compressor to cool down properly between cycles This will help the unit run more efficiently as several runs per hour will increase compressor tempera tures thus requi...

Страница 5: ......

Страница 6: ...as indicator lights to show when the compressor is ON or when the unit is on DEFROST mode ADJUSTMENTS ITEMS TO REMEMBER FOR NORMAL OPERATION SET THE UNIT TO 35 F PLEASE NOTE THAT THIS IS NOT THE INTERNAL REFRIGERATOR CABINET TEMPERATURE DO NOT CHANGE THE TEMPERATURE SETTING MORE THAN 3 F AT A TIME This does not apply when adjusting the unit to the default setting or making broad adjustments to a d...

Страница 7: ... this point press the SET once more and use the c or d keys to reach the number 22 on the screen this is your password 5 Press the SET key once more to return the display to PS 6 Use the c or d keys to cycle through the different programming parameters 7 ALWAYS Press the SET button for at lest 5 seconds to exit the programming mode Review Please verify all programmed operational variables accordin...

Страница 8: ... Duration 4 4 Hours c6 Alarm Delay after continuous cycle 2 2 Hours DEFROST PARAMETERS d0 Defrost type 0 heater 1 Hot Gas 2 timed heater 3 timed HG 2 3 dI Defrost interval 4 8 Hours dt Defrost Ends Temperature 50 4 F dP Max Defrost Duration 30 30 Minutes d4 Defrost after power on 0 NO 1 YES 0 0 d5 Defrost delay after power on 0 0 Minutes d6 Block Display during Defrost 0 NO 1 YES 1 1 dd Dripping t...

Страница 9: ... will turn OFF and will remain off until it reaches 38 F Due to the 3 F differential temperature cycle It is important to understand that your product will not actually reach 38 F The average product temperature will settle somewhere midway between the ON and OFF set points approximately 37 F depending on the product type Please refer to the following graph for a representation of the refrigeratio...

Страница 10: ...L BLOCK 210 0302 ELECTRICAL COMPONENTS CONDENSER FAN 210 0105 MAIN POWER SWITCH 210 0021 LIGHT BULB COATED 210 0245 MAIN POWER CORD 210 0287 LIGHT SOCKET 210 0314 ARFG 42 SERVICE PARTS LISTING The following is a list of all components and or hardware that are serviceable on the ARFG 42 refrigera tor unit Please refer to the picture and attached text for reference and identification ...

Страница 11: ...R HINGE REPLACEMENT KIT 290 0155 EVAPORATOR COIL FINGER GUARD 200 0182 REFRIGERATION COMPONENTS REFRIGERANT COMPRESSOR 260 0055 EVAPORATOR COIL 250 0057 CONDENSER COIL 250 0061 HARDWARE COMPONENTS DRAWER GASKET 290 0164 DOOR GASKET 290 0165 CONDENSER FAN FINGER GUARD AND MOTOR MOUNT 210 0253 ...

Страница 12: ... Hardware components Cont EVAPORATOR FAN BLADE 210 0315 FOOD PAN 1 2 SIZE x 6 D 290 0130 QTY 2 CONDENSER FAN BLADE 210 0250 SHELF PILASTERS 290 0186 QTY 4 SHELF CLIP 290 0140 QTY 4 ...

Страница 13: ... Louver Panel for Island ...

Страница 14: ......

Страница 15: ...L HELP AND SERVICE For service please contact our Alfresco Gourmet Grills authorized service agency at 1 866 203 5607 Please provide Model Number Serial Number Date of installation A brief description of the problem For all other Alfresco Gourmet Grill product inquiries please contact Alfresco Gourmet Grills Customer Service Department 7039 East Slauson Avenue Commerce CA 90040 888 383 8800 or 323...

Отзывы: