8
BRIQUETTE TRAY INSTALLATION:
GAS CONNECTION—LIQUID PROPANE (LP)
NEVER CONNECT THE GRILL TO AN UNREGULATED GAS SUPPLY.
Before proceeding, ensure the unit is fitted for LP gas. Connecting to an improper gas type will result in
poor performance and increased risk of damage or injury. Total gas consumption (per hour) with all
burners set on “HI” is a follows:
•
30” Grill
71,000 BTU
•
42” Grill
101,500 BTU
•
56” Grill w/ side burners
136,500 BTU
•
Dual Side Burners
35,000 BTU
The installation of this appliance must conform with local codes or, in the absence of local codes, to the
national fuel gas code, ANSI Z223.1a-1988. Installation in Canada must be in accordance with the Stan-
dard CAN/ CGA-B149.1 Natural Gas Installation or CAN/CGA-B149.2, Propane Installation Code.
Manifold pressure with LP
Operating: 10.0” W.C.
Non-operating:
11.2” W.C.
L.P. TANK REQUIREMENTS:
Use only a standard 20 Lb. (5 Gal.) propane gas cylinder (18-1/4” H x 12-1/4” Ø). The tank must be in-
stalled in the upright position. Do not use a dented or rusty LP tank as it may be hazardous and should
be checked by your LP supplier. Never use a cylinder with a damaged valve.
Remove top grill.
Briquette tray located over the
gas burners