13
Start-up
You have received a completely assembled magnetic drill stand and detailed operation manual. Please check the
condition of the goods on receipt for any transport damage, and make sure the delivery is complete. Otherwise
contact the manufacturer immediately.
Always read the operation manual before using the device for the first time!
1.
First, open the quick clamping lever and set the drilling machine as complete as possible into the tool holder.
The nose (see red mark) should be used as a torque support to avoid inadvertent twisting of the drilling
machine.
2.
Close the quick clamping lever tightly.
3.
The lever of the switchable permanent magnet is pointing upwards. The magnet is deactivated so that you can
position the machine. A slight magnetic pre-tension helps with alignment of the machine on vertical walls or for
overhead work. Secure the drilling unit using the safety belt when working on walls and ceilings.
4.
Press the lever down as far as it will go. Make sure that the safety tab audibly latches into place. The magnet
is now activated.
Before drilling, make sure that the lever of the magnet is in the ON position.
5. After having activated the magnet, insert the plug of the drilling machine in the mains socket and turn the
motor on.
6. Turn the star handle to lower the motor and the rotating drill slowly to the workpiece. Ensure sufficient
cooling during the drilling process.
7. When you have finished drilling, move the motor upwards by turning the star handle. Deactivate the motor
of the drilling machine and pull the plug.
8. Once the motor has come to a complete standstill, remove swarf and other drilling waste.
9. To deactivate the permanent magnet, press the black safety tab inwards using the ball of your hand and lift
the lever up. Then clean the underside of the magnet of swarf or any other residue stuck to it.
Use a swarf hook to remove the swarf. Do not touch with your bare hands. Risk of injury!