background image

16 
 

Positioningthe Pump during Operation 

 
The tank of the AHP pump is closed by the ventilation screw and thus is not sealed. To prevent the hydraulic oil 
inside the tank from leaking or overflowing, the pump must not be used at a sharp slope. 
When the pump is used frequently, foam can occur on the oil surface which, when the pump is used in a highly 
sloped position, can flow out of the ventilation screw into the oil tank vent. It is preferable to align the pump 
horizontally. 

 

 

 

 
 
 

Oil Change 

 

Regular maintenance of the pump will extend the lifetime of seals and moving parts. If the hydraulic pump is used 
frequently, the oil must be completely replacedto eliminate suspended matter and deposits.The first oil change 
should be carried out after approximately 50 hours of operation. Be sure to change the hydraulic oil once a year.  
 

 

Wear safety goggles and ear protection!  

 
 

1.  Disconnect the pump from the mains. 

 

2.  Remove t

he plug bolt and screw the 1/2“ threaded nozzle (2) with the silicon hose (1) into the opening of 

the tank. 
 

3.  Incline the pump forward and let the oil flow into a collection container. 

 
 

 

 

4.  Turn the pump to a horizontal position and remove the threaded nozzle and the silicon hose. Refill the tank 

with hydraulic oil type HLP 46 (approx. 3 litres). 

 

 

Deaerate the pump before using tools and cylinders for the first time!  

 

5.  To deaerate the pump, put the coupling piece onto the final coupling of the hose set.

 

Содержание AHP-L 23190

Страница 1: ...Mode d emploi Instrukcja obsługi tłumaczenie ALFRA Hydraulikpumpe AHP L Elektrische Hydraulikpumpe Electric Hydraulic Pump Pompe hydraulique électrique Elekrohydrauliczna pompa Art Nr 23190 Prod No 23190 N de produit 23190 Artykuł nr 23190 ...

Страница 2: ...ation check electric and hydraulic connection cables for damage make sure the mains voltage matches the machine follow the instructions in these operation instructions familiarize new users with the safe use of this machine wear safety goggles and ear protection during work observe local country specific guidelines store in a dry and well ventilated place Never modify this machine or remove signs ...

Страница 3: ...pressure 700 bar 10150 psi Max delivery volume 1 7 l min 0 45 gal min Tank volume 3 0 l 0 79 gal Operating volume 2 2 l 0 58 gal Weight 35 kg 70lbs Noise emission 92 dB A 300 mm distance from the motor Vibration on the handle AC 3 5 mm s and VC 3 2 mm s AvailableAccessories Prod No Extension hose On request ALFRA Service Boy transport cart 23160 Hydraulic oil HLP 46 5 l 3000 ...

Страница 4: ...running and equipped with an operating capacitor 12 and a start capacitor 14 The integrated magnetic valve 16 controls the generated oil flow and maintains the pressure within the tool when the pause function is activated If the working pressure inside the tool exceeds the maximum regulated pressure of the pump the excess pressure valve 15 opens and guides the oil back into the pump tank The oil t...

Страница 5: ...nge This will allow the air to flow through the oil tank 5 Connect the control cable of the toolto the 5 pole flange socket 6 Turn the main switch to the position I to switch the pump on and to put it into standby mode 7 Position the desired material in the tool and ensure a central position according to your application Be sure to observe the operation and safety instructions of the connected too...

Страница 6: ...frequently the oil must be completely replacedto eliminate suspended matter and deposits The first oil change should be carried out after approximately 50 hours of operation Be sure to change the hydraulic oil once a year Wear safety goggles and ear protection 1 Disconnect the pump from the mains 2 Remove the plug bolt and screw the 1 2 threaded nozzle 2 with the silicon hose 1 into the opening of...

Страница 7: ... in the operating manual and according to the country specific standards and regulations Maintenance testing and repair work may only be carried out by qualified electricians according to the regulations valid in the respective country The maintenance intervals are classified according to the frequency with which the maintenance should be carried out Always disconnect the machine from the mains be...

Страница 8: ...tion is not dimensioned sufficiently Use another protection circuit breaker 16A type B Does the PCB work properly Is the mains voltage applied to the motor cable or the motor terminal box The PCB is defective or incorrectly connected Have the electrical connection checked and repaired by a qualified electrician Replace the component or have the pump repaired by the distributor or manufacturer Is i...

Страница 9: ...r manufacturer Is the magnetic valve energized and does it conduct the oil flow tothe tool Push the plastic cap of the valve and feel if there is a slight movement The magnetic valve is defective or overheated Replace the component or have the pump repaired by the distributor or manufacturer Check the power supply of the magnetic valve Wrong commanding signal or defective PCB Have the electrical c...

Страница 10: ... EMC 2004 108 EC RoHs Directive 2011 65 EU Following directives or normative documents were applied Machinery Directive EN 61029 1 2009 Low Voltage Directive EN 60204 1 2006 A1 2009 EN 60034 1 2010 EN 60034 5 2001 A1 2007 EMC Directive EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 RoHs Directive EN 50581 2012 Authorized for the ...

Отзывы: