16
Er04
Turning off due to excessive water temperature in the boiler
Er05
Turning off due to excessive flue gas temperature
Er06
Safety thermostat activated on the auger housing
Er07
Encoder error. Missing signal
Er08
Encoder error. Inability to adjust number of revolutions
Er09
Water pressure too low
Er10
Water pressure too high
Er11
Error due to internal clock problem
Er12
Turning off due to unsuccessful ignition
Er15
Power failure longer than 50 minutes
Er16
Communication error RS485
Er17
Airflow regulator error
Er18
No pellets
Er25
Cleaning engine error
Er39
Airflow regulator broken
Er41
Minimum airflow in the CHECK UP stage has not been reached
Er42
Maximum airflow achieved
Er47
Auger encoder signal error
Er48
Error due to the inability to adjust the speed of the auger
Er52
Module I/O I2C Error
-
Other messages:
Sond
This message displayed in the Check-Up stage indicates that the temperature at one or
more probes is equal to the minimum value (0°C) or the maximum value (depends on the
probe type). Ensure that the probe is not open (0°C) or in short circuit (the maximum value
on the temperature scale).
Service
This message informs you that the planned number of work hours is reached and that it
is necessary to call the service.
Clean
This message informs you that the planned number of work hours is reached and that
general cleaning of the stove is necessary.
Block Ignition
This message appears when the system turns off while it is still in the ignition stage. The
system will stop working only when it enters the Run Mode.
Link Error
This message informs you that there is no communication between the LCD display and
the controller of the stove.
Standby Man
Appears if the system is in Standby mode due to the pressed button P5
-
Visualizations:
By pressing the P4 and P6 buttons the visualization menu is entered. In this menu you can see the values of some system
parameters.
L3 On P1 Pump
LED number and output status of the pump
L4 Off Safety Valve
LED number and output status Aux 1
L5 Off Out not used
LED number and output status of the additional
engine
L6 On Load Engine
LED number and output status Aux 2
L7 Off Out not used
LED number and output status Aux 3
Exhaust T.:103
Flue gases temperature (°C)
Water T.: 55
Water temperature (°C)
Buffer T.: 52
*Buffer temperature (°C)
Room T.: 21
Room temperature (°C)
Pressure: 1548
*Pressure of water in the boiler (mbar)
Air Flux: 680
Primary air flow rate (cm/s)
Speed Fan: 1000
Speed/voltage of flue gas engine (rpm/V)
Auger ON: 800
Speed/voltage of auger engine (rpm/V)
Product Code 448-0000
System code
FSYD01000135.0.2
Controler firmware version
PSYSF01000209.0.2
Display firmware version
*In case the stove configuration has no installed probes these values are not visible.
MENU
The menu contains the User Menu and the Technical Menu.
The Technical Menu contains the settings and setup, through which the manufacturer can modify the parameters and
configuration of the system. The Technical Menu is not available to the user but only to the authorized representative of the
manufacturer.
User Menu (User menu)
By pressing the P3 button the User Menu is entered.