background image

14 

Loose knobs or 
some screw on 
the solid fuel 

Tighten knobs and screws 

11  Sounds in the pump 

The pressure at 
the pump suction 
part is to low 

Increase system pressure or check the expansion vessel. 

12 

The 

solid 

fuel 

overheats,  loud  noise 
(cracking)  is  heard  in 
the  boiler  of  the  solid 
fuel. 
 

Electricity  outage 
has  occurred,  the 
circulation  pump 
does  not  work 
and  the  boiler  of 
the 

solid 

fuel 

overheats.  There 
is  a  danger  of 
boiler rupture. 
 
 

To avoid this occurrence, it is best to have backup battery power supply 
of the circulation pump with an inverter. 
 
Installation  of  a  thermal  exhaust  valve  (Fig.  7,  pos.  13)  is  required  as 
additional security against solid fuel overheating. 
 

If  you  do  not  have  backup  supply  of  the  circulation  pump  or  a  thermal 
exhaust valve installed, then you should open the bypass valve connected 
in  parallel  with  the  circulation  pump  on the pipeline system and remove 
embers from the solid fuel. 

13 
 
 
 
 
 
 
 
 

Cooling  thermal  fuse 
is  activated  (thermo 
valve) because  
water temperature 
increased over 95

due to: 

- loss of 
electricity  

This  is  proper  and  do  not  touch  anything.  When  the  system  is  cold, 
thermal valve will be closed. 
After that, check the pressure in the installation and fill the system to the 
required. 

- open ashtray 
door and no 
regulated 
combustion 

Close the ashtray door and through the knob on the cover of the ashtray 
door and thermostat, reduce the water temperature in the system. 

- the grate is in 
lower position 
and small number 
of radiators are 
switched on 

Transfer the grate to upper position or switch on some other radiator. 
Keep the ashtray door closed. 

14 

Water condensate in 
the boiler 

Damp heating 
material 

Change heating material 

Too low 
temperature of 
returning water 
from the heating 
system 

Insert combined valve or switch off some radiator from the heating 
system 

15 

Outlet water 
temperature is not 
appropriate (low) 

Non-calorific 
heating material  

Change heating material 

Heating system is 
oversized 
(a large number of 
radiators) 

Switch of some radiators 

Little heating 
material is 
inserted in the 
firebox 

Increase the quantity of heating material in the firebox 

16 

Fire does not burn 
regularly  

Weak flue draft 

Make a new flue or repair the old one 

Flue pipe 
connections do 
not seal.  
The doors on the 
solid fuel and the 
flue do not seal. 
The flue draws 
“false air”. 

Seal all connecting spots so that “false air” would not occur 

17 

There is not enough 
heat in baking, 
cooking 

The thermostat is 
set to a lower 
temperature 

Increase water temperature through a thermostat or shortly open the 
ashtray door 

18 

There is too much heat 
in baking, cooking 

The thermostat is 
set to a high 
temperature 

Reduce water temperature through the thermostat or stoke moderately  

19 

The boiler-solid fuel 
releases smoke during 
initial startup 
 

Combustion and 
heating of the 
solid fuel and  flue 

It is normal for the solid fuel to release some smoke during initial startup, 
and this stops after some time.  

20 

The boiler-solid fuel 
releases smoke during 
regular use 

Uncleaned flue, 
flue pipes and 
solid fuel 

Clean the internal part of the flue, the flue pipe and solid fuel. 

Содержание ALFA TERM -27

Страница 1: ...ALFA TERM 27 This product meets the requirements of the Ecodesign Directive in terms of efficiency and air pollution level in order to contribute to the reduction of energy consumption and negative en...

Страница 2: ...eating power is shown for stoking dry beech wood with lower heating power Hd 4255W kg DEAR BUYERS Thank You for the trust you showed us buying our stove for floor heating We assure You that You have c...

Страница 3: ...2 1 THERMAL VALVE WITH BUILT IN THERMAL PROTECTION Fig 7 Item 13 and Fig 7a 7 7 2 2 SLOPE PRESSURE REGULATOR 1 2 WITH MANOMETER Fig 7 Item 19 and Fig 7b 8 7 2 3 WATER FILTER OF THE BOILER INTAKE Fig...

Страница 4: ...CKAGING MAY CAUSE SUFFOCATION THESE INCLUDE PLASTIC BAGS FILMS STYROFOAM ETC 2 3 THE RESPONSIBILITY OF THE INSTALLER The responsibility of the installer is to perform all the checkups of the flue pipi...

Страница 5: ...Secondary air regulator knob 19 Ash pan door 10 Thermostat combustion regulator knob 12 Ash pan ash box 13 Grate holder 14 Wood box 15 Cleaning access plate 16 Pressure gauge 17 Thermometer 18 Cooktop...

Страница 6: ...inet is mounted above the stove minimum clearance between the stove s cooktop and the cabinet should be at least 40 cm Combustible materials e g wallpapers door casings doors etc require a clearance t...

Страница 7: ...box and screw it on the outlet on the cooktop or on the side outlet First remove the cover and use the same screws to fasten the collar NOTE If your chimney is of unsatisfactory or dubious quality we...

Страница 8: ...is built on the outside walls it must be well insulated If the chimney connection is tightly connected to the chimney if the connection is extended If it is properly cleaned and free of birds nests di...

Страница 9: ...ney pipes that have a rectangular internal cross section with a ratio that differs from the plan Modest efficiency 40 Chimney positioning and distance 7 INSTALLING THE STOVE IN THE WATER HEATING SYSTE...

Страница 10: ...ssure regulator with manometer 1 2 the same or similar as shown in Fig 7b and Fig 7 Item 19 3 Filter for cold water at the input of the water supply to the thermal valve Fig 7 Item 20 4 Filter for hot...

Страница 11: ...the hot boiling water from dirt and solid objects that can damage the tap seals or seals of the thermal valve This filter must be resistant to water temperatures up to 150 C NOTES After the completio...

Страница 12: ...losed expansion vessel 7 Contact thermostat Note It is mandatory to install a thermal discharge valve with thermal protection the so called thermal fuse in accordance with the recommendations from the...

Страница 13: ...ected to the chimney as described in the foregoing items NOTE The stove may not be used without water It must be connected to the system which is connected to consumers radiators with the power of no...

Страница 14: ...d using the thermostat power regulator combustion regulator which is located in the ash pan door and which automatically sets the regulator damper depending on the regulation knob setting Fig 1 Items...

Страница 15: ...odors the next time you heat the oven Clean the cooktop occasionally using fine sandpaper and in the event of longer breaks apply acid free oil on the cooktop vegetable oil Remove burnt material from...

Страница 16: ...t If water is leaking from the valve replace the expansion vessel If only air comes out from the valve remove the installation vessel and pump it The pressure in the vessel must be equal to or greater...

Страница 17: ...small number of radiators are switched on Transfer the grate to upper position or switch on some other radiator Keep the ashtray door closed 14 Water condensate in the boiler Damp heating material Cha...

Страница 18: ...ate of undesirable objects 18 Outline dimensions of ALFA TERM 27 stove Figure 16 19 DETERMINING THE REQUIRED HEAT OUTPUT There is no absolute rule that would allow the calculation of the required heat...

Страница 19: ...eating close the air inlet covers and DO NOT open the fireplace door Extinguish the fire with appropriate means home fire extinguisher NEVER USE WATER TO EXTINGUISH THE FIRE Also notify local firefigh...

Отзывы: