Maintenance and repair

New seal install

To place the new valve seal, place the seal at
the entrance of the opening. The conical side
needs to be orientated toward the interior.
 
With the help of a 7mm drill mounted upside
down in a drill press (used as a press), press
the new seal in its emplacement with caution

To  reassemble,  make  sure  to  re-screw  the  valve
by  hand  firmly  as  well  as  the  lever  to  close  the
valve.
Then you can re-screw the M3x8 Allen screw on
the side of the metallic part with a 1.5 mm key.
 

Warning : the screw need to remain 1mm
out from the metallic surface (can be
measured with slidding calliper)

Once all the internal parts reassembled, you can replace the back cover of the
Tyrecontrol as well as the batteries and batteries cover with the srews previously
unscrewed

Warning

During disasemble or reasemble of parts, make sure to not damage any mechanical or
electronical parts.
 
For any questions or hesitations, do not hesitate to contact Alfano S.A. : 
 

Rue de l'Industrie, 3B

B-1400 Nivelles (Belgique)

Phone: +32(0)67 410 846

Email : [email protected]

Содержание A1950

Страница 1: ...Manual EN A1950...

Страница 2: ...ou to reduce but also increase pressures thanks to its air cartridge Doing so you gain autonomy and control over your tyres and the ability to analyze their data in the Alfano 6 App Product Reference...

Страница 3: ...elect a tyre Short Push Turn Off Long push Turn on Turns off after 10min of inactivity Record pressure for the selected tyre Backlighting On Off turns off after 10 sec of inactivity Short and long pus...

Страница 4: ...llows thanks to its innovative valve to use Air Cartridges available in sport shop like Decathlon cycling shop or website like Ebay or Amazon Warning During cartridge replacement it s imperative for t...

Страница 5: ...ed your Tyrecontrol Air will show the logo TRANSFER Once the data transfered to your Alfano 6 you will find all the informations in your App by clicking on the Session info icon Transfer the pressure...

Страница 6: ...ximum of 0 2 Bar 20 PSI This type of setting is used in competition to modify on screen information and mislead not informed personnel competitors technical spy others page 5 Firmware version and seri...

Страница 7: ...ge it s imperative that the withdrawned cartridge is empty and the valve openned All actions done without respecting these recommendations could deteriorate your device or create risks of injuries Bef...

Страница 8: ...Maintenance and repair Repair kit Seals placement 1 O ring CO cartridge 2 O ring valve 3 Valve seal special part Screw and washer to replace the valve joint 1 2 3...

Страница 9: ...e a leak near the lever to add pressure Defective seal removal Once the cartridge uninstalled in respect of security rules you can proceed to dismantle the top part of the lever in open position This...

Страница 10: ...done using a 2 mm Allen key Then remove the rotation valve in accordance to instructions explained in the previous chapter Once removed you can proceed to dismantle the batteries cover and the back c...

Страница 11: ...crew the M3x8 Allen screw on the side of the metallic part with a 1 5 mm key Warning the screw need to remain 1mm out from the metallic surface can be measured with slidding calliper Once all the inte...

Отзывы: