20/25
ALFA IN a.s.
©
www.alfain.eu
P3
Connector of the remote control (connect to matching connector
A3
on the front panel)
1.
When you connect the connector
P3
to matching connector
A3
on the front
panel, the function setting the current from the torch will be automatically
blocked.
2.
By means of the encoder
V22
set maximal required value of the current.
3.
Set the machine to the mode
2T
.
4.
By pressing the stepping surface
P1
down, you start the welding process.
The value of the welding current depends on the level of pressing the
stepping surface. To reach the maximal current, set by the encoder
V22
,
requires to gently pressing to the lowest position of the stepping surface
P1
. The set current will be displayed on the current display
V4
see fig. n.
3.
5.
The welding process ends after releasing the stepping surface
P1
.
8. TWO STOKE AND FOUR STROKE IN TIG MODE
TWO STROKE – 2T
Gas
Pregas
Postgas
Down slope
Current
Welding current