23
Special maintenance
Special cleaning and maintenance activities (types 2 and 3) help the furnace keep its heating and functional
characteristics for longer.
To ensure that the maintenance of the furnace is not in vain, it is necessary to maintain the system for removing smoke
with the same diligence.
SPECIAL MAINTENANCE TYPE 2 ACTIVITIES
In addition to type 1 maintenance activities, type 2 maintenance activities must be carried out after about 350-400
working hours, or otherwise after about 500 ~ 600 kg of used fuel.
⚠
ATTENTION: Any cleaning activity must be carried out when the furnace is completely cold and disconnected from the
power supply (with a cable unplugged from the socket).
⚠
ATTENTION: Make sure that the ash is completely cold before you start cleaning the furnace. When you make sure the
ash is cold, you can clean it with a vacuum cleaner.
Periodic type 2 maintenance activities are carried out in accordance with the following procedure:
1.
Lift and slide the heat-resistant plate on the top of the furnace inward so that the lower part is sticking out.
2.
Take the heat-resistant plate with both hands and tilt it from the combustion chamber making sure that the plate
does not hit other parts of the furnace.
3.
Thoroughly clean the entire back part of the heat exchanger using the attached brush and a vacuum cleaner to
clean up all the soot and ashes that come out of the heat exchanger,
After you've finished cleaning, re-assemble all the elements in reverse order from the order in which you removed them.
SPECIAL TYPE 3 MAINTENANCE ACTIVITY
These activities should be carried out at the end of the season, along with the type 1 of routine maintenance activities
and special type 2 maintenance activities.
These special maintenance activities serve to clean the engine smoke and its cabinet, as well as to carry out a thorough
cleaning of the lower part of the heat exchanger.
You should perform these activities from both sides of the furnace by removing the outer insulation (see the instructions
with the isolation kit for removing the housing).
⚠
ATTENTION: These activities should be performed by an authorized person.
⚠
ATTENTION: Any cleaning activity must be carried out when the furnace is completely cold and disconnected from the
power supply (with a cable unplugged from the socket).
⚠
ATTENTION: Make sure that the ash is completely cold before you start cleaning the furnace. When you make sure the
ash is cold, you can clean it with a vacuum cleaner.
Engine smoke and its housing can be cleaned by following the activities described below:
1.
After lifting and removing the lid, you can lift up and remove the left side. Do the same on the right side.
That’s how you can get excellent access to the engine smoke.
Engine smoke