![Alfa Plam COMMO COMPACT Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/alfa-plam/commo-compact/commo-compact_installation-operation-and-maintenance-manual_2895408021.webp)
21
Figure 28
15.2.2 Failed ignition
Once a period of 20 minutes runs out, if the temperature of smoke did not reach the minimally allowed value of
45ºC, the stove transfers to the state of an alarm, see point 15.6.3.
15.2.3 Stove in operational mode
If the stage of ignition is positively done i.e. if the temperature of flue gases had reached a value of
45ºC for less than 20 minutes, the stove transfers to the operational mode WORK that represents its normal
manner of functioning.
15.2.4. Adjustment of the temperature of the room and the water in the boiler
For the adjustment of the temperature of the room and the water in the boiler, it is sufficient to press the buttons 1 or
2. The display will show the current state of the set temperature (T
SET
).
The stove has been factory set with a temperature of water in the boiler of 65ºC and at room temperature of 20ºC.
By pressing the button 1, the message SET TEMP. WATER is shown (figure 29) i.e. adjusted value of the
water temperature in the boiler. Thus, with button 1 we increase and with button 2 we reduce the value of the
temperature and in this manner we adjust the desired value of the water temperature in the boiler. The temperature
of water can be adjusted within the range from 40ºC to 80ºC. We recommend that you do not adjust the water
temperature below 50 – 55ºC due to possible condensation of the boiler, neither above 75ºC.
Figure 29
By pressing the button 2, the message SET TEMP. ROOM is shown (figure 30) i.e. set value of the
temperature in the room. Thus, with button 1 we increase and with button 2 we reduce the desired value of the
temperature in the room. The temperature in the room can be adjusted within the range from 7ºC to 40ºC.
Figure 30
15.2.5. The temperature of the room or the temperature of water in the boiler reaches the desired
temperature
When the temperature of the room or the temperature of water in the boiler has reached the desired value (T
SET
),
the heating power is automatically transferred to a minimal value, the stove transfers to an economical operational
mode, whereupon savings in fuel are achieved, and the display shows the message WORK MODULAT as shown in
figure 31:
Figure 31
If after this, the temperature of the room or of the water in the boiler reaches a value which is for 4 ºC bigger than
the given ones (T
SET
+ 4ºC), the mode STAND-BY activates, the stove temporarily switches off. It switches on again
when the following conditions have been fulfilled:
T
prostorije
< (T
SET
– 4ºC)
15.2.6. Setting the stove power