8
DO NOT approach and touch the door of the combustion chamber while the boiler is operating. There is a RISK OF
BURN INJURIES.
DO NOT approach or touch the flue pipe, while the boiler is operating. There is a RISK OF BURN INJURIES.
During operation, DO NOT clean the heating installation.
DO NOT open the firebox door while the boiler is operating, as it works properly only if the door is sealed.
DO NOT remove ash when the boiler is operating.
DO NOT allow children and animals to approach the pellet boiler .
ADHERE TO THE INSTRUCTIONS STATED IN THIS DOCUMENT
Follow the below tips for correct use of the boiler :
Only use fuel recommended by the boiler manufacturer.
Observe the maintenance instructions.
Clean the firebox after consuming 100 to 200 kg of pellets (every 3 to 4 days, only when the boiler and ash in it are
cool).
DO NOT use the pellet boiler if there are any breakdowns or other irregularities, unusual sounds, and /or if you suspect
there is a breakdown. Contact your authorized maintenance centre IMMEDIATELY.
DO NOT pour water on the boiler with or use water to extinguish fire in the combustion chamber.
DO NOT lean on the boiler because it may not be stable enough and can overturn.
DO NOT use the pellet boiler as a support or as a means of supporting other objects. Do not leave the pellet tank open.
DO NOT touch the painted parts of the boiler during operation.
DO NOT use wood or coal in the pellet boiler ; use only pellets of the following characteristics:
dimensions: diameter 6 mm
maximum length: 30 mm
moisture: up to 10%
heating value: min. 16.9 MJ / kg, or 4.7 kWh / kg
ash content: below 0.7%
DO NOT use the boiler for burning garbage.
Always take care of maximum safety.
GUIDELINES FOR SAFE IGNITING AND CLEANING THE BOILER
NEVER use fuel oil, petroleum or similar products, or other flammable liquids to start fire in the boiler . While the boiler is in
operation keep such and other liquids away from it.
Make sure the pellet boiler is properly positioned and that it does not move.
Make sure the firebox is well closed and remain closed during operation of the pellet boiler .
Remove ash only while the pellet boiler is cold.
Do not use abrasive cleaning agents for cleaning the pellet boiler .
ROUTINE MAINTENANCE AND CLEANING THE BOILER
Using vacuum cleaner ash facilitates removing the ash from the boiler .
Before proceeding with any maintenance or cleaning procedures, observe the following safety rules:
Turn off the pellet boiler before starting any procedure.
Before starting any boiler maintenance activity, make sure the ash is cold.
Use protective gloves for cleaning.
You need to know what the better and cleaner the pellet, the less frequently you need to clean and maintain the boiler .
CLEANING THE FIREBOX
Clean the firebox every 3-4 days.
Open the upper exterior door of the boiler (Figure 10a).
Open the combustion chamber door (Figure10b).
Lift the firebox handle using the enclosed wrench (Fig. 10c), then lift the firebox and remove the firebox from its casing
(Figure 10d).
Turn the firebox and pour the ash and slag into the garbage bin. Then brush the sides and the bottom of the support
with a brush and sharp object so that all openings on the firebox are clean.
Finally, use a vacuum cleaner to clean the inside of the firebox (Fig. 10e).
Figure 10a
Figure 10b
Figure 10c