The fluid recommended in the installation is water and glucose antifreeze of 30%. 
 

Note: 

At reaction, and valve operation, during fluid cooling in an overheated boiler part of the new fluid is injected into 
the boiler, but the part is also ejected from the boiler. It will be poured down the drain. If the antifreeze is in the 
installation you must keep in mind that a certain percentage will go out and pour down the drain! 
We recommend the thermal valve Caleffi type 544, 1/2" as shown in Figure 7a. 
 

6.2.2 SLOPE PRESSURE REGULATOR 1/2" WITH MANOMETER (Fig. 7, Item 19 and Fig. 7b) 

When installing the thermal valve it is required to mount the slope pressure regulator as shown in Fig. 7, Item 
19. The pressure that is maintained by pressure regulator must be set at a higher pressure than the pressure 
that  is  in  the  heating  system.  If  you  do  not  have  a higher water pressure of at least 0.8 bar compared to the 
pressure in the heating system thermal valve will not work or cannot inject cold water into the boiler that needs 
to be cooled. 
Pressure regulator should be set to 2.8 to 3 bars. 
You should take into account the direction of placing the slope pressure regulator! 
 

6.2.3 WATER FILTER OF THE BOILER INTAKE (Fig. 7, Item 20) 

In front of the slope pressure regulator on water intake from water supply line it is necessary to install a filter 
that  will  clean  the  water  from  solid  objects,  primarily  of  sand, which  can  damage  the  tap  seal  or seals of the 
thermal valve and the slope pressure regulator. 
This filter does not need to be resistant to high water temperatures due to cold water that flows through. 
 

6.2.4 WATER FILTER OF THE BOILER OUTLET (Fig. 7, Item 21) 

It  is  required  to  install  the  filter  on  the  boiler  outlet which  will  clean  the  hot  -  boiling  water  from  dirt  and  solid 
objects that can damage the tap seals, or seals of the thermal valve. 
This filter must be resistant to water temperatures up to 150°C. 
 
 

NOTES: 

- After the completion of thermal valve activation, checking the pressure in the installation and filling the system 
with cold water is mandatory. 
-  In  cases  where  antifreeze  is  used,  after  filling  the  installation  with  water  it  is  required  to  check  percentage 
content of antifreeze in a mixture of water and antifreeze! 
-  To  avoid  elimination  of  the  antifreeze  agent  solution  from  the  installation,  it  is  best  to  have  backup  battery 
supply of the pump with an inverter. 

6.3 SAFETY VALVE (Fig. 7 and 8, Item 5 and Fig. 4, Item 6) 

An R1/2" connection (Fig. 4, Item 6) is welded at the back of the boiler, under the cooktop frame, on which  a 
safety valve MUST be fitted. The safety valve should be 2.5 to 3 bars. You can fit it directly on the connection 
or at a distance from the connection of at least  1 m, provided that there is no block valve between the boiler 
and the safety valve. 
In general, safety valve is not fitted in open circuits, but we advise you to fit it nonetheless, as another safety 
precaution for the boiler and the system (in case of emergency). 

NOTE: 
If the safety valve is not fitted as described above, the warranty will not be valid. 

6.4 THERMOMETER AND PRESSURE GAUGE (Fig. 1, Items 16 and 17 and Fig. 5) 

Thermometer and pressure gauge are installed on the stove, on the additional lid (Fig. 1, Item 24) between the 
firebox  door  and  the  ash  pan  door  (Fig.  1,  Items  16  and  17,  and  Fig.  5)  and  therefore  it  is  not  necessary  to 
install them. 
Thermometer, Item 17, shows the temperature of water in the boiler (operating temperature) in 

ºC. 

Pressure gauge, Item 16, shows the pressure of water in the boiler or the system in bars. 

 
 
 
 
 
 
 
 
 
 

                          Figure

 

5       

 

 

 

 

            Figure 6 

Содержание ALFA TERM 27

Страница 1: ...STOVE USED FOR LOCAL HEATING ALFA TERM 27 INSTALLATION SETUP AND OPERATION INSTRUCTIONS ...

Страница 2: ...ENSIONS Width 315 mm Height min max 264 460 mm Depth 414 mm FIREBOX DOOR OPENING width height 175 200 mm FLOW AND RETURN PIPE CONNECTIONS R1 RS THERMO VALVE AND SAFETY VALVE CONNECTIONS R1 2 RU COOLING PIPE CONNECTIONS R1 2 RS BOILER VOLUME 25 l HEATING VOLUME WITH THE GRATE IN DOWN POSITION 340 450 m3 total Heating volume by radiation of heat 90 115 m3 Hot water radiator heating volume 250 335 m3...

Страница 3: ...Smoke pipe connection 21 Cleaning access plate 22 Handle 23 Grate support 24 Additional lid 25 Lever support 26 Tertiary air regulator knob 27 Tertiary air regulator cover 28 Cleaning access plate smaller 30 Tertiary air regulator 3 SAFETY AND RELIABILITY OF STOVE OPERATION The stove used for local heating is designed to ensure maximum operational safety Stove operational safety is ensured by the ...

Страница 4: ...4 Figure 1 ...

Страница 5: ... and not on the side outlet The stove will reach its nominal heating capacity if the draft in the chimney is 20 Pa A chimney ensuring good draft is the basis of proper functioning of the stove The chimney not only affects the stove s output but also the combustion quality Chimney draft directly depends on the chimney s cross section height internal wall roughness and the difference between the tem...

Страница 6: ...if the connection is extended If it is properly cleaned and free of birds nests dirt and soot If the flue pipe does not enter deeply inside chimney opening since this reduces the space for the smoke to exit If all other required openings and cleaning access plates are well shut sealed to prevent generation of false air If its duct is independent from other installation and has no cap on top Figure...

Страница 7: ...g 7a and Fig 7 Item 13 2 Slope pressure regulator with manometer 1 2 the same or similar as shown in Fig 7b and Fig 7 Item 19 3 Filter for cold water at the input of the water supply to the thermal valve Fig 7 Item 20 4 Filter for hot boiling water intake of the boiler and water outlet of thermal valve Fig 7 Item 21 Note These components are not included with product for central heating you bought...

Страница 8: ...red to install the filter on the boiler outlet which will clean the hot boiling water from dirt and solid objects that can damage the tap seals or seals of the thermal valve This filter must be resistant to water temperatures up to 150 C NOTES After the completion of thermal valve activation checking the pressure in the installation and filling the system with cold water is mandatory In cases wher...

Страница 9: ...lose to the boiler as possible and no block valves can be fitted between the boiler and expansion vessel INSTALLATION DIAGRAM OF STOVE WITH CLOSED CENTRAL HEATING SYSTEM ALFA TERM 27 Figure 7 1 Hot water boiler 2 Flue pipe connection 3 Distribution pipe 4 Closed expansion vessel 5 Safety valve 6 Radiator valve 7 Radiator 8 Air vent valve 9 Circulation pump 10 Return pipe 11 Charge and discharge co...

Страница 10: ...tarts to leak and then close them Do not discharge water from the heating system even during summer because it protects the inside of the system from oxidation corrosion If you will not use the boiler for a longer period during winter and no antifreeze mixture is pored into the system it is best if you discharge water from the system While discharging the system open the radiator valves air releas...

Страница 11: ...ation in the stove After plenty of hot fragments have formed load the portions of coal in two or three steps at 15 minute intervals Figure 12 9 USING THE GRATE IN THE UP AND DOWN POSITION For cooking baking and heating during transitional season the grate is in up position Fig 11 to ensure that the flame directly reaches the cooktop and saves cooking baking and heating costs The stove is delivered...

Страница 12: ...burning wood and open it when burning coal 12 COOKING BAKING AND FRYING During heating season the stove is used mainly for heating For faster baking cooking and frying use only dry firewood The damper used for starting the fire must be closed and power regulator must be open After you finish baking cooking or frying place the power regulator in desired position While baking increase the temperatur...

Страница 13: ...ly if any repairs need to be carried out on the installation If the system is not used during heating season poor a certain amount of antifreeze liquid into the system or discharge the water to prevent freezing 16 TROUBLESHOOTING Table 3 No Problem Possible cause Repair 1 Water pressure in the system dropping slowly Installation is not sealed Check whether all welded connections threaded connectio...

Страница 14: ...sing a screw gun until the rotor can move freely The pump is blocked due to deposits Dismantle and clean the pump 9 Thermometer or pressure gauge does not display system temperature or pressure Faulty thermometer or pressure gauge Replace thermometer or pressure gauge Faulty pump Large clearance between the rotor axis and nut Reduce pump speed Replace pump nuts or the entire pump 10 Noise murmur c...

Страница 15: ...ow chimney draft Build a new chimney or repair the old one Connecting flue pipes are not sealed Stove and chimney door are not sealed Chimney draws false air Seal all joints to prevent occurrence of false air 17 Insufficient heat for baking or cooking Thermostat set to a low temperature Increase water temperature using the thermostat or briefly open the ash pan door 18 Excessive heat for baking or...

Страница 16: ...cal damaging by the buyer if the defect occurred after too strong or insufficient power as well due to force major We can repair the defects of Your device also outside the guaranteed period with original spare parts for which we also provide a guarantee under the same conditions This guarantee does not exclude or affect the rights of the customer in regard to the conformity of the goods pursuant ...