Alfa Network ALP 44 Скачать руководство пользователя страница 8

 

 

 

ENTERING THE MENU ANG CHANCING THE PARAMETERS: 

 

 In order to switched to programming mode while device operating mode, pressed at the same time (      ) 
button and (      ) button.  Firstly “



”menu will appear on the screen. 

 

 

Switch between program menus with Down (      ) and up (      ) buttons. PRG button is entered into for the 
menu to be changed. Changes are saved with prg (     ) button. Return to operating mode with Rst (      ) 
button.  If  password  protection  is  activated  at  device,  password  must  be  entered.  If  password  is  correct, 
true message is displayed on the bottom line. Also password is incorrect, “errP” is displayed. 

 

 

 

 

 

 

Menu  is  displayed  firstly  on  the  screen  as prg  button  is pressed  while  operating mode.  Menu  of  Set  2  is 
displayed while down button is pressed. The top row shows the name of the menu and bottom row also 
(yellow marked) selected value in menu content. Set 1, set 2 allows controlling to out1 and out2 relays.  

Move to the desired set point for setting.  The rightmost digit starts flashing when Prg button is pressed. 
Desired point is selected up and down button. Used to Prg button for digits scrolling. Shifted to the left for 
one step when each press of the button, if pressed the prg button when coming the rightmost digits, 
positive or negative value will be asked. Value is selected by up and down button then saved with prg 
button. If you do not want to save, you can exit with esc button. 

 

 

 

 

 

 

 

 

 

 

4.

 

S

ETTINGS

 

 



.





.







.









.







If Password is correct : 

 

If Password is incorrect : 

 

 

4.1. Entering The Set Point to Device (Set) 



.





.



The rightmost digit starts flashing when Prg button is 
pressed. Desired point is selected up and down 
button. Used to Prg button for Digits scrolling. Save 
with prg button. 

 



.






.



- 6 - 

Содержание ALP 44

Страница 1: ...UTPUT TIME ADJUSTABLE SCREEN REFRESH RATE ENTERING OF HYSTERESIS SELECTABLE POINT POSITION TARE FUNCTION ABS REL 0 1 ACCURACY ENTERING OFFSET VALUE PASSWORD PROTECTION USER MANUAL MEASUREMENT INSTRUME...

Страница 2: ...ection of point position decp 7 4 4 Entering of scale value s lo s hi 7 4 5 Automatic calibration fcal 8 4 6 Manuel calibration c lo c h 8 4 7 Span menu span 9 4 8 Reset selection tare 9 4 9 Entering...

Страница 3: ...V 0 4 20 mA Current Input ALP44A OUTPUTs Analogue 0 10 V Optional 4 20 mA Optional OUTPUTs Contact 2 unit 250 VAC 3A for Resistive Load Relay Serial Communication RS 232 Optional PHYSICAL CHARACTERIST...

Страница 4: ...f fall snap shake during working 4 Make Sensor connections without energy on the device do not connect in any way during operation 5 Make sure that is shielded cables between device and sensor 6 Do no...

Страница 5: ...3...

Страница 6: ...4...

Страница 7: ...On while Set 2 value is displayed in the bottom display 7 LED of TARE LED status of Tare Absolute Relative Function Button Functions 8 PROG Button Operating Mode Used to return to the menu with Tare...

Страница 8: ...The top row shows the name of the menu and bottom row also yellow marked selected value in menu content Set 1 set 2 allows controlling to out1 and out2 relays Move to the desired set point for setting...

Страница 9: ...xample this provides that a potentiometer is shown 0 or others value at minimum position stroke length or others value at maximum position Likewise this situation also applies to the pressure transmit...

Страница 10: ...nus C LO menu provides to entered minimum position value C HI menu also entered maximum position value C LO menu sets the potentiometer is in the closed position and also C HI menu sets in the opened...

Страница 11: ...ssed at Span menu bottom row menu content flashes Change the choice with up down buttons Tare function will be active at on position and also inactive at off position Save selection with prg button T1...

Страница 12: ...s situations If password is incorrect you cannot make any change Password is not requiered while secu menu is off SPS1 menu is added to menu titles while Secu menu is nset position SPS2 menu is also a...

Страница 13: ...7600 bps Data bits 8 Stop bits 1 Parity none 999999 message is displayed on the screen when value is too high Scale or format value can be minimized 999999 message is displayed on the screen when valu...

Страница 14: ...tput 4 20 mA Output Serial No This product is guaranteed for two years against manufacturing defects Conditions out of the warranty Mechanical damage Shipping damage Users error Other situations are c...

Страница 15: ...evizli Mah Bagdat Cad Guven Sok No 11 TR 34846 Maltepe Istanbul TURKEY Tel 90 216 399 44 04 Fax 90 216 399 44 02 Web www ateksensor com E Mail info ateksensor com Iran agent a Tel 021 66 3939 00 Mob 0...

Отзывы: