3 Installation
Study the instructions carefully and pay special attention to the warnings!
The valve has ends for welding as standard.
Weld carefully/aim at stressless welding to avoid deformation on sealing areas.
Check the valve for smooth operation after welding.
3.4
Welding
Step 1
Never stick your fingers in the operating parts of the valve if the
actuator is supplied with compressed air.
2319-0180
!
Step 2
Dismantle the valve in accordance with the description of dismantling the valve, see 5.2 Dismantling of valve
Step 3
Before welding the valve into the pipe line please note:
1. Maintain the minimum clearances "A" so that the actuator with
the internal valve parts can be removed - please see later on
in this section!
If there is a risk of foot damage, Alfa Laval recommends leaving
a distance of 120 mm (4.7”) below the valve (look at the specific
built-in conditions).
ISO
DIN
Size DN/OD
51
DN/OD
63.5
DN/OD
76.1
DN/OD
101.6
DN
50
DN
65
DN
80
DN
100
A
265
300
300
360
265
290
270
350
B*
835
970
980
1175
835
970
980 1175
C
73.8
86.3
96.9
123.6
76
92
107
126
NOTE! If ThinkTop® is mounted, add 180 mm (7,1") to B measure.