Page 10 Instruction Manual, Alfa Laval Potentiometric Level Transmitter
TE91K021-EN5
5. Installation
Mounting with Unique Flexbody Connection:
The TE67H is available with the Unique Flexbody connection which offer a 100% flush connection in tanks. .
Mounting with 3-A approved welding adaptor
For the TE67H06xxxxxxx to be compliant to 3-A it must be installed in the welding adaptor
TE67N000000010. The TE67N000000010 welding adaptor can be fitted on the top of the
tank.
It is important that the installation comply to 3-A regulations which means that:
Only 3-A approved welding adaptor is to be used (TE67N000000010)
The inspection hole should be visible and drained
Mount the adapter in a self-drained position/angle
The 3-A mark or the arrow shall be placed upwards
Welding should be grinded to Ra=0.8
Welding according to appropriate 3-A standard
TE67N000000010 is also available with (these are not included in the 3-A authorization):
Electropolishing: TE67N000000017
3.1 certificate: TE67N000000028
Electropol 3.1 certificate: TE67N000000035
.