![Alfa Laval LKH Evap Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/alfa-laval/lkh-evap/lkh-evap_instruction-manual_2895070031.webp)
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Lubricate the rubber seals before fitting them.
: Relates to the shaft seal.
S
Stteepp 55
1. Fit impeller (36/37) on stub shaft (7).
2. Ensure that the clearance between the impeller and back plate (25) is correct: 0.5 mm (0.02 inch) for LKH Evap-10 to 60 and
1.0 mm (0.039 inch) for LKH Evap-70 to -75.
3000-0104
LKH Evap-10 to -60 = 0.5 mm (0.02 inch)
LKH Evap-70 to -75 = 1.0 mm (0.039 inch)
S
Stteepp 66
Clear Flow impeller
3000-0161
N
NO
OTTE
E!! If pump is mounted with “ClearFlow” impeller the clearence must be adjusted from the knobs to backplate.
S
Stteepp 77
1. Remove impeller (36/37), back plate (25) and drive ring (52).
2. Tighten screws (6) evenly to 15 Nm (11 lbf-ft).
Counterhold with a screwdriver
15Nm
(11 lbf-ft)
3000-0109
31
CONTACT CSI FOR MORE INFORMATION | CSIDESIGNS.COM | [email protected] | 417.831.1411