Speed Adjustment
Type 1
Before the speed can be adjusted, the Power Unit and turbine must be drained from oil.
Loosen the nut on the turbine shaft and adjust the turbine to desired position.
Reduce measure A to reduce speed.
Increase measure A to increase speed.
The turbine speed depends on the liquid flow, which in turn depends on the supply pressure and nozzle dia.
Type 2
Loosen the lock nut and turn on the adjusting screw.
Clockwise to increase the speed.
Anti-clockwise to reduce the speed.
When desired speed is set, tighten up the lock nut.