6 Technical Data
23
It is important to observe the technical data during installation, operation and maintenance.
Inform personnel about the technical data.
6.1 Technical Data
The Alfa Laval GJ PF-FT Tank Cleaning Machine is a highly efficient machine at a range of pressures and flows. The instruction
manual is part of the delivery. Read the instruction carefully.
TECHNICAL DATA
Lubricant
……………………………. Self-lubricating with the cleaning fluid
Max. throw length
………………….. 14 – 20 m (45 - 65 ft.)
Pressure
Working pressure …………………. 3 – 28+ bar (40 – 400+ PSI)
Recommended pressure ………… 4 – 20 bar (50 – 300 PSI)
Cleaning Pattern
First Cycle
Full Pattern
The above drawings show the cleaning pattern achieved on a cylindrical horizontal vessel. The difference between the first
cycle and the full pattern represents the number of additional cycles available to increase the density of the cleaning.
Certificate
2.1 Material Certificate
PHYSICAL DATA
Materials
1.4404 (316L), PPS, FKM, (EPDM and FKM available).
Temperature
Max. working temperature
………… 95°C (203°F)
Max. ambient temperature
………… 140°C (284°F)
Weight
………………………………. 4.3 kg (9.5 lbs.)
Surface finish
………………………0.5 µm (20 Ra)
Connections
Available option
……………………. 1 ½” weld, 1 ½” tri-clamp, 1 ½” ISO 2037 slip fit, 1 ½” DIN R1 slip fit, 1.5” DIM R2 slip fit
Standard thr
ead ……………………. 1 ½” Rp (BSP) or NPT, female
Options
Electronic rotation sensor to verify 3D coverage.
Caution
Do not use for gas evacuation or air dispersion.
Содержание GJ PF-FT