21/24
ALFA IN a.s. ©
www.alfain.eu
Fig. 11.
Connection of the main TIG components
1. Connect the TIG torch
B12
to the quick connector of welding cables (-)
A6
,
to the gas connector
B14
and connector
B10
.
2. Connect the ground cable
B9
to the
quick connector of welding cables (+)
A2
and
the ground clamps
B11
to the welder
B7
or to the welding table
.
3. Connect the machine to power supply and turn the main switch on the rear
panel to ON.
4.
Connect
the
gas hose and
gas flow adjustment
described
in ADJUSTMENT
OF GAS FLOW.
5. Press the button
V19
to select the mode
TIG
. LED
V3
lights up.
6.
By means of the potentiometer
V7
adjust
the welding current.
7.
By means of the potentiometer
V8
adjust
the time of Down Slope.
8. By means of the potentiometer
36
you can change the time of
Pre Gas
.