SAFETY INSTRUCTIONS AND WARNINGS 

 

OPERATION AND MAINTENANCE OF PLASMA ARC EQUIPMENT CAN 
BE DANGEROUS AND HAZARDOUS TO YOURHEALTH. 

 

Plasma arc cutting produces intense electric and magnetic emissions that 
may interfere with the proper function of cardiac pacemakers, hearing aids, 
or other electronic health equipment. Persons who work near plasma arc  
cutting applications should consult their medical health professional and 
the manufacturer of the health equipment to determine whether a hazard 
exists. 

 

Once the packing has been opened, make sure that the machine is not 
damaged. If in any doubt, call the service centre. 

 

This equipment must only be used by qualified personnel.  

 

During installation, any electric work must only be carried out by trained 
personnel. 

 

The machine must be used in a dry place with good ventilation. 

 

Make sure that no metal dust can be drawn in by the fan inside the 
machine, as this could cause damage to the electronic circuits. 

 

It is prohibited to connect more than one INVERTER generator in series or 
in parallel. 

 

When installing the machine, follow the local regulations on safety. 

 

The position of the machine must allow easy access by the operator to the 
controls and connectors. 

 

When the cutting machine is operating, all its covers and doors must be 
closed and well fixed. 

 

Do not expose the cutting machine to direct sunlight or to heavy rain. This 
equipment conforms to protection rating IP23S. 

 

The operator must wear gloves, clothes, shoes, and a helmet or a welder’s 
helmet, which protect and are fire-resistant in order to protect him against 
electric shock, flashes and sparks from cutting. 

 

The operator must protect his eyes with safety visor or mask designed for 
welding, fitted with standard safety filters. He should also be aware that 
during plasma cutting ULTRAVIOLET RADIATION is emitted. Therefore it 
is vital that his face is also protected from radiation. Ultraviolet rays 
produce the same harmful effect as sun burning on unprotected skin.  

 

The operator is obliged to warn anyone near the cutting area of the risks 
that cutting involves and to arrange to provide adequate protection 
equipment. 

 

Keep all fumes and gases from the breathing area. 

 

Keep your head out of the fume plume. 

 

Use an air-supplied respirator if ventilation is not adequate to remove all 
fumes and gases. 

Содержание PEGAS 40 PLASMA PFC

Страница 1: ...ALFA IN a s www alfain eu NA124 103 PLASMA CUTTING MACHINE PEGAS 40 PLASMA PFC OPERATING MANUAL...

Страница 2: ...ECHNICAL DATA 8 5 OPERATOR CONTROLS 9 5 1 FRONT AND REAR PANELS 9 6 ACCESSORIES 10 6 1 PART OF DELIVERY 10 6 2 ON REQUEST 10 6 3 COMMENTS ON CONSUMABLES 12 7 GETTING STARTED 12 7 1 FIRST STEPS 12 7 2...

Страница 3: ...Manual and your employer s safety practices before installing operating or servicing the equipment While the information contained in this Manual represents the Manufacturer s best judgement the Manuf...

Страница 4: ...l When installing the machine follow the local regulations on safety The position of the machine must allow easy access by the operator to the controls and connectors When the cutting machine is opera...

Страница 5: ...ur hearing from loud noise wear protective ear plugs and or ear muffs Protect others in the workplace Noise levels should be measured to be sure the decibels sound do not exceed safe levels The operat...

Страница 6: ...hanically with increased protection for the operator DC current 141V peak value AC current 141V peak value and 100V effective 4 Plasma cutting DC current 500V peak value In case 1 the dc machines with...

Страница 7: ...covers It is forbidden to operate the machine in wet environments and outdoors in rain or snow Ensure proper grounding clamping pliers which also reduces the risk of electric shock Use prescribed pro...

Страница 8: ...A PFC Unit Method Plasma cutting Mains voltage V Hz 1 x 110 50 60 1x230 50 60 Mains protection A 20 T 16 T Max input power I1 A 33 7 23 4 Max effective current I1eff A 19 9 14 8 Cutting current range...

Страница 9: ...ve the machine on to cool down Second warning is when the mains voltage is over 270 V 3 Cutting current potentiometer 4 LED Error 1 LED illuminates and the air valve regularly opens and closes there i...

Страница 10: ...or electrodes 6 ACCESSORIES 6 1 PART OF DELIVERY Plasma cutting torch ABICUT45 6 m with cutting tip 0 8 mm and shield cup 35 A 6 2 ON REQUEST Pos Item No Description V9030038 Earthing cable with clamp...

Страница 11: ...45 19 748 0035 10 Cutting Tip 0 8 Standard ABI25 45 19 748 0061 10 Cutting Tip 1 0 Standard ABI25 45 20 748 0049 10 Cutting Tip 0 9 Long ABI25 45 21 748 0042 2 Shield Cup ABI25 45 25A 21 748 0052 2 Sh...

Страница 12: ...ing in angles or in spaces where standard electrode cannot reach It is possible to drag the Long cutting tip directly on the cutting material up to thickness of 5 8 mm without the guiding spring The L...

Страница 13: ...the torch with appropriate type of cutting tip electrode and shield cup according to the selected cutting current 7 2 REQUIREMENTS FOR SOURCE OF COMPRESSED AIR Delivered air pressure must be max 8 ba...

Страница 14: ...cuts of excellent quality To achieve a good cutting quality make sure the distance between the tip and the material is about 2 mm The Standoff Guide ABI25 45 pos 21 located at the end of the plasma t...

Страница 15: ...d is highly dependent on compliance with the principles of good cutting Disconnect the machine from the mains before replacing the torch consumable parts Unplug the machine from the mains before any i...

Страница 16: ...orch The worn parts consumables of a plasma torch should be regularly maintained and timely exchanged Regularly check the condition of diffuser channels see diagram of the torch If contaminated you mu...

Страница 17: ...workmanship when operated in accordance with the written instructions as defined in this operating manual ALFA IN products are manufactured for use by commercial and industrial users and trained pers...

Страница 18: ...ALFA IN 10 DISPOSAL Only for EU countries Do not dispose of electric tools together with household waste material In accordance with European Council Directive 2002 96 EC on electrical and electronic...

Отзывы: