Alfa IN PEGAS 250 MIG MAN Скачать руководство пользователя страница 15

Page 15 of 15 

 

ALFA IN  a.s. ©                                  

 

 

   

www.alfain.eu

 

components that fail due to defects in material or workmanship within the 
warranty period. The warranty period begins on the date of sale to the 
end user. 

 

If warranty is being sought, please contact your ALFA IN product supplier 
for the warranty repair procedure. 

 

ALFA IN warranty will not apply to: 

 

Equipment that has been modified by any other party other than 
ALFA IN’s own service personnel or with prior written consent 
obtained from ALFA IN Service Department. 

 

Equipment that has been used beyond the specifications established 
in the operating manual. 

 

Installation not in accordance with the installation/operating manual. 

 

Any product that has been subjected to abuse, misuse, negligence or 
accident. 

 

Failure to clean and maintain (including lack of lubrication, 
maintenance and protection), the machine as set forth in the 
operating, installation or service manual. 

 

Within this operating manual are details regarding the maintenance 
necessary to ensure trouble free operation. 

NOTE 

 

 

Warranty repairs must be performed by either an ALFA IN Service 
Centre, an ALFA IN distributor or an Authorised Service Agent approved 
by the company ALFA IN. 

11.  DISPOSAL 

Only for EU countries. Do not dispose of electric tools together with 
household waste material.  

In accordance with European Council Directive 2002/96/EC on 

electrical and electronic equipment waste and its implementation in 
accordance with national law, electric tools that have reached the end of 
their service life must be collected separately and returned to an 
environmentally compatible recycling facility. 

 

Содержание PEGAS 250 MIG MAN

Страница 1: ...N PEGAS 320 MIG MAN INSTRUCTION MANUAL Content 1 INTRODUCTION 2 2 SAFETY INSTRUCTIONS AND WARNINGS 2 3 CONDITIONS OF USE 6 4 TECHNICAL DATA 7 5 ACCESSORIES 7 6 DESCRIPTION OF THE APPLIANCE 8 7 GETTING...

Страница 2: ...nes are designed to produce maximum power output combined with high reliability and efficiency 2 SAFETY INSTRUCTIONS AND WARNINGS OPERATION AND MAINTENANCE OF WELDING EQUIPMENT CAN BE DANGEROUS AND HA...

Страница 3: ...ep all fumes and gases from the breathing area Keep your head out of the fume plume Use an air supplied respirator if ventilation is not adequate to remove all fumes and gases The kinds of fumes and g...

Страница 4: ...nected to the return wire The earthing of the piece being worked could increase the risk of injury to the operator EN 60974 1 Standard Open circuit voltage During the operation of the machine the high...

Страница 5: ...electromagnetic emissions generated could prove not be compatible with the maximum permitted levels for some classes of electrical equipment such as the following Domestic electronic appliances radio...

Страница 6: ...the health equipment to determine whether a hazard exists Never aim the torch against the eyes body or other person 3 CONDITIONS OF USE This equipment must only be used by qualified personnel During i...

Страница 7: ...rent DC 100 I2 U2 A V 210 24 5 210 24 5 Welding current DC 60 I2 U2 A V 250 26 5 250 26 5 Welding current DC x I2 U2 A V 60 250 26 5 25 315 29 8 Voltage setting continuous continuous Insulation class...

Страница 8: ...core wires Torches with UP DOWN remote control Welding torches see the table below Ordering No 018 D975 1 Torch ABIMIG AT 305 C LW 3m 018 D976 1 Torch ABIMIG AT 305 C LW 4m 018 D977 1 Torch ABIMIG AT...

Страница 9: ...inated the machine is ON 9 LED indicator if illuminated the welder is over heated or the mains voltage is out of range 10 2 stroke 4 stroke switch 11 Wire feeding button 12 Choke potentiometer 13 Quic...

Страница 10: ...ctor Earthing cable Fig 1 13 C2 Earthing clamp B1 EURO connector Fig 1 1 B2 Torch Euro Connector Male B3 Welding Torch Connect the earthing clamp C2 to the welding piece Connect the B1 and B2 torch co...

Страница 11: ...at way that it provides constant movement of wire but it does not deform wire 7 2 CHANGING THE WIRE FEEDER ROLL Every wire feeding roll in ALFA IN machines can be used for two different diameters of w...

Страница 12: ...3 5x1 5mm G5 Nut G6 Teflon Liner G7 Sustain pipe for teflon and plastic liner 7 4 GAS FLOW SETTING The electric arc and the weld must be perfectly shielded by gas Too small amount of gas does not perf...

Страница 13: ...of gas on the reduction gas valve it is not a part of the welding machine by the F7 adjusting screw Release the button 11 for digital 8 WELDING For orie ntating adjusting of the welding current and vo...

Страница 14: ...der should also be wiped clean If necessary solvents that are recommended for cleaning electrical apparatus may be used Troubleshooting and repairing of ALF welding equipment should only be carried ou...

Страница 15: ...ted to abuse misuse negligence or accident Failure to clean and maintain including lack of lubrication maintenance and protection the machine as set forth in the operating installation or service manu...

Отзывы: