2. SAFETY INSTRUCTIONS AND WARNINGS 

1.  Once  the  packing  has  been  opened,  make  sure  that  the  machine  is  not 

damaged. If in any doubt, call the service centre. 

2.  This equipment must only be used by qualified personnel.  
3.  During  installation,  any  electric  work  must  only  be  carried  out  by  trained 

personnel. 

4.  The machine must be used in a dry place with good ventilation. 
5.  Make sure that no metal dust can be drawn in by the fan inside the machine, 

as this could cause damage to the electronic circuits. 

6.  It is prohibited to connect more than one INVERTER generator in series or in 

parallel. 

7.  When installing the machine, follow the local regulations on safety. 
8.  The position of the machine must allow easy access by the operator to the 

controls and connectors. 

9.  When  the  welding  machine  is  operating,  all  its  covers  and  doors  must  be 

closed and well fixed. 

10.  Do not expose the welding machine to direct sunlight or to heavy rain. This 

equipment conforms to protection rating IP23S. 

11.  During welding, the welding cables must be located near or at ground level. 

They should be as short as possible. 

12.  The operator must wear gloves, clothes, shoes, and a helmet or a welder’s 

helmet,  which  protect  and  are  fire-resistant  in  order  to  protect  him  against 
electric shock, flashes and sparks from welding. 

13.  The operator must protect his eyes with safety visor or mask designed for 

welding, fitted with standard safety filters. He should also be aware that during 
electrical welding ULTRAVIOLET RADIATION is emitted. Therefore it is vital 
that  his  face  is  also  protected  from  radiation.  Ultraviolet  rays  produce  the 
same harmful effect as sun burning on unprotected skin.  

14.  The operator is obliged to warn anyone near the welding area of the risks 

that  welding  involves  and  to  arrange  to  provide  adequate  protection 
equipment. 

15.  It  is  very  important  to  arrange  for  sufficient  ventilation,  especially  when 

welding  in  enclosed  spaces.  We  suggest  using  suitable  fume  extractors  to 
prevent  the  risk  of  intoxication  by  fumes  or  gas  generated  by  the  welding 
process. 

16.  The operator must ensure all flammable materials are removed from the 

work area to avoid any risk of fire. 

17.  The operator must NEVER weld containers that have previously contained 

petrol,  lubricants,  gas  or  similar  flammable  materials,  even  if  the  container 
has been empty for a considerable time. THERE IS A VERY HIGH RISK OF 
EXPLOSION. 

18.  The operator must be aware of all the special regulations which he needs 

to conform to when welding in enclosed spaces with a high risk of explosion. 

19.  To prevent electric shock, we strongly suggest the following rules:  

a.  Do not work in a damp or humid environment. 

Содержание 5.0284

Страница 1: ...ALFA IN a s www alfain eu PEGAS 201 MIG SYN PFC manual EN 04 WELDING MACHINE PEGAS 201 MIG SYN PFC OPERATING MANUAL...

Страница 2: ...INSTRUCTIONS AND WARNINGS 4 3 TECHNICAL DATA 6 4 EQUIPMENT 7 5 MAIN PARTS OF THE MACHINE 8 6 MAIN MENU 10 7 GETTING STARTED MIG MAG 13 8 GETTING STARTED TIG 20 9 GETTING STARTED MMA 21 10 ROUTINE MAIN...

Страница 3: ...sumes no liability for its use The model of PEGAS 201 MIG SYN PFC is the multi function inverter power generators welding by those methods a MIG MAG in 2T 4T manually or synergic wires G3Si1 or stainl...

Страница 4: ...in order to protect him against electric shock flashes and sparks from welding 13 The operator must protect his eyes with safety visor or mask designed for welding fitted with standard safety filters...

Страница 5: ...as possible must never exceed the values relating to the various cases shown in the following table Case Working conditions Open circuit voltage 1 Places with increased risk of electric shock DC curre...

Страница 6: ...cuit voltage U20 V 67 0 67 0 Mains protection A 25 16 Max effective current I1eff A 22 0 17 5 18 0 14 9 15 7 12 0 Welding current DC 100 I2 A 85 65 95 130 120 140 Welding current DC 60 I2 A 110 80 125...

Страница 7: ...PFC VM0321 3 Hose Gas 3m Pegas MIG without G1 4 4314 Quick connector Pegas 160 40 part of hose VM0321 3 VM0253 Welding Cable Set 2x 3m 35 50 200A Rolls see section WIRE FEEDER 4281 Pressure Reducer AR...

Страница 8: ...AIN PARTS OF THE MACHINE Fig 1 PEGAS 201 MIG SYN PFC Pos Description A1 MIG MAG torch connector A2 Quick connector of welding cables or TIG torch A3 Gas connector for TIG torch A4 Knob A5 Display A6 K...

Страница 9: ...ON OFF A10 Mains cable A11 Gas connector A12 Handle A13 Spool holder A14 Switch Spool Gun A15 Terminals of change polarity MIG MAG torch A16 Wire feeder WIRE FEEDER Fig 2 Wire feeder Pos Description E...

Страница 10: ...www alfain eu OVERVIEW OF ROLLS FOR WIRE FEED a b a 22 mm b 30 mm Groove type Wire diameter Item No Steel 0 6 0 8 2187 0 8 1 0 2188 Aluminium 0 8 1 0 2270 Flux core 0 8 1 0 2318 1 0 1 2 2319 6 MAIN ME...

Страница 11: ...umber material of welding wire protective gas and wire diameter 8 Multifunctional window Press MENU button to move between submenus METHOD SELECTION Rotate and then press the knob A4 for method select...

Страница 12: ...Synergic parameters selection SECONDARY WELDING PARAMETERS SELECTION Rotate the knob A4 and then press the knob A6 for parameters settings Fig 7 Secondary welding parameters selection Secondary weldi...

Страница 13: ...Getting started must be consistent with technical data and conditions of use CHOOSING THE FEEDING ROLL In all machines ALFA IN MIG MAG rolls with two grooves are used These grooves are intended for tw...

Страница 14: ...the gear fit and fix it by setting the lever E1 into vertical position 5 Adjust the pressure nut that way that it provides constant movement of wire but it does not deform wire The adjusting screw is...

Страница 15: ...Notice When inserting the wire do not point with torch to the eyes 5 Remove the gas nozzle from the torch 6 Unscrew the current nozzle 7 Connect the machine to power supply 8 Turn the main switch A9...

Страница 16: ...e bottom side pressure reducing valve until the meter F6 shows the required flow then release the button The optimum flow is 10 15l min 4 After long term shutdown of the machine or replacement of the...

Страница 17: ...eter settings ADJUSTING THE MACHINE FOR ANOTHER WIRE DIAMETER In all machines ALFA IN MIG MAG are used rolls with two grooves These grooves are intended for two different wire diameters e g 0 8 a 1 0...

Страница 18: ...eans the bridge K3 with K4 terminal Use Phillips screwdriver 5 Make sure you fasten the terminals properly 6 Connect the ground cable to the quick connector Fig 13 Terminals for changing the polarity...

Страница 19: ...it is also necessary to provide the torch tefl liner and special current nipple We do not recommend you to use the torch longer than 3 m Great attention must be paid to adjust the contact power of rol...

Страница 20: ...ck connector B9 of welding cables and the ground clamps B11 to the weldment B7 or to the welding table 3 Connect the machine to power supply and turn the main switch on the back panel to ON 4 Connect...

Страница 21: ...N MENU 3 Select the current 10 ROUTINE MAINTENANCE INSPECTION 1 The only routine maintenance required for the PEGAS range of machines is a thorough cleaning and inspection with the frequency depending...

Страница 22: ...tten instructions as defined in this operating manual 2 ALFA IN welding products are manufactured for use by commercial and industrial users and trained personnel with experience in the use and mainte...

Страница 23: ...a warranty list serves proof of purchase invoice on which is the serial number of the machine 12 DISPOSAL Only for EU countries Do not dispose of electric tools together with household waste material...