Alex-Tronix Filter Master Series Скачать руководство пользователя страница 8

OPERATING CHARACTERISTICS

The unit can initiate a backwash cycle by PD or Periodic time or both, and manually. When a 

backwash initiates, the FM-4P moves out of filtering mode, and individually washes each tank. The 

systems pressure differential drops when cycle is complete, and the tanks are deemed clean. If the 

pressure does not drop, troubleshooting of the filter system itself should be performed, starting with 

solenoid and valve maintenance. Additional troubleshooting resources can be sought out on the tech 

support page on the web at: www.alextronix.com  

FUSE REPLACEMENT :

 

Should the fuse ever blow, the following symptoms should be examined:

Ÿ

Solenoids defective or become defective when heated for long periods.

Ÿ

Primary voltage too high.

Ÿ

Short circuit in solenoid wiring.

CAUTION: Replace fuse with same type only! – 20mm 1.6amp Slow Blow.

For any questions or help regarding this controller please contact us at 1-888-224-7630.

For questions regarding you filter system, contact the manufacturer.

   

WARRANTY

Suppliers and end users of this product agree to the following terms, conditions and limitations of warranty and liability coverage:

Alex-Tronix warrants the F4P to be free from original defects for two years from the date of original sale. The manufacturer shall replace, 

free of charge any part found defective under normal use and service within the guarantee period, provided the product is installed, used, 

and maintained in accordance with any applicable instructions or limitations issued by Alex-Tronix. Components supplied replacement 

parts are warranted for 90 days from the date of shipment. The manufacturer assumes no liability for incidental or consequential damage 

sustained in the adoption or use of our engineering data, service, or products. Liability is therefore limited to the repair of the product 

manufactured by Alex-Tronix. No agent or representative of Alex-Tronix has the authority to waive or add to this agreement.  Altered 

products, or use of products in a manner not intended shall void this warranty. For warranty service, ship unit pre-paid to the address 

below. Controllers damaged in transit due to improper packaging are not covered by warranty.

For warranty repair, send defective product freight pre-paid to:

Alex-Tronix Controls Div. GNA Industries   - 4761 W. Jacquelyn Ave. Fresno, CA. 93722 -  Tel: (888)-224-7630   Fax: (559) 276-2890

www.alextronix.com -  [email protected]

Содержание Filter Master Series

Страница 1: ...FM 4P Filter Backwash Controller IMPORTANT Prior to use please read manual in order to avoid system damage Alex Tronix FILTER MASTER SERIES REV 021418...

Страница 2: ...panel to AC or DC DCL NOTE Setting the switch to DC output when using transformer is only for use with DC non latching solenoids DC input from alternator For DC operation remove the A C transformer a...

Страница 3: ...l battery and controller are connected in parallel NOTE POLARITY OR NOTE INSTALL 2 AMP FUSE AT POWER SOURCE FOR ALL DC INPUT APPLICATIONS FM 4P FILTER BACKWASH CONTROLLER ON FUSE 20mm 1 6A S B Y O Y C...

Страница 4: ...C M 1 2 3 4 B B W R _ SENSOR 24VAC C T OR 12VDC FILTER TANKS GAUGE SERIAL 4 B W R FIG 2 SOLENOID WIRING CONFIGURATION OPTIONS SOLENOID SOLENOID SOLENOID SOLENOID SOLENOID PRESSURE SUSTAINING MASTER VA...

Страница 5: ...E FM 4P FILTER BACKWASH CONTROLLER ON FUSE 20mm 1 6A S B Y O Y C M 1 2 3 4 B B W R _ SENSOR 24VAC C T OR 12VDC FILTER TANKS GAUGE SERIAL 4 B W R 0 15 PSI C N O MURPHY SWITCH GAUGE OR ANY PRESS DIF SWI...

Страница 6: ...Function Selector Knob Use this knob to select which function you wish to view or program There is no specific setting this knob must be set to for normal operation as long as FM 4P is correctly prog...

Страница 7: ...en Press SELECT and to set the delay time up to 255 seconds Contact filter manufacturer for correct setting TANK ASSIGN Depending on how many filter tanks there are you can activate deactivate any of...

Страница 8: ...ons of warranty and liability coverage Alex Tronix warrants the F4P to be free from original defects for two years from the date of original sale The manufacturer shall replace free of charge any part...

Отзывы: