background image

Confidential 

Alesis Service Manual 

8-31-0092-A 

Safety Instructions 

 
Carefully read the applicable items of the operating instructions and these safety 
suggestions before using this product. Use extra care to follow the warnings 
written on the product itself and in the operating instructions. Keep the operating 
instructions and safety suggestions for reference in the future.   
 

1. Power 

Source. The product should only be connected to a power supply which is described 

either in the operating instructions or in markings on the product. 

 
2. Power 

Cord 

Protection. AC power supply cords should be placed such that no one is likely to 

step on the cords and such that nothing will be placed on or against them. 

 
3.  Periods of Non-use.  If the product is not used for any significant period of time, the product's 

AC power supply cord should be unplugged from the AC outlet. 

 
4.  Foreign Objects and Liquids.  Take care not to allow liquids to spill or objects to fall into any 

openings of the product. 

 
5.  Water or Moisture.  The product should not be used near any water or in moisture. 
 
6. Heat.  Do not place the product near heat sources such as stoves, heat registers, radiators or 

other heat producing equipment. 

 
7. Ventilation.  When installing the product, make sure that the product has adequate 

ventilation. Improperly ventilating the product may cause overheating, which may damage the 
product. 

 
8. Mounting.  The product should only be used with a rack which the manufacturer 

recommends.  The combination of the product and rack should be moved carefully.  Quick 
movements, excessive force or uneven surfaces may overturn the combination which may 
damage the product and rack combination. 

 
9. Cleaning.  The product should only be cleaned as the manufacturer recommends. 
 
10. Service.  The user should only attempt the limited service or upkeep specifically described in 

the operating instructions for the user.  For any other service required, the product should be 
taken to an authorized service center as described in the operating instructions. 

 
11.  Damage to the Product.  Qualified service personnel should service the unit in certain 

situations including without limitation when: 
a.  Liquid has spilled or objects have fallen into the product, 
b.  The product is exposed to water or excessive moisture, 
c.  The AC power supply plug or cord is damaged, 
d.  The product shows an inappropriate change in performance or does not operate 

normally, or 

e.  The enclosure of the product has been damaged.

Содержание M1 Active MKII

Страница 1: ...leged and confidential information It is intended only for the use of those authorized by Alesis If you are not the authorized intended recipient you are hereby notified that any review dissemination distribution or duplication of this document is strictly prohibited If you are not authorized please contact Alesis and destroy all copies of this document You may contact Alesis at servicemanuals ale...

Страница 2: ... to the Manual shall be solely your responsibility and Alesis shall have no liability for any such repairs or service work All such service or repairs are performed at the sole risk of the person performing the service or repairs You agree that all such work will be performed in a competent professional and safe manner at all times and to indemnify and fully hold Alesis and its successors and assi...

Страница 3: ...ZED REPAIR SERVICE CENTER IN THE PROVISION OF REPAIR SERVICES OR TO BE OR MAKE REPAIRS AS AN AUTHORIZED SERVICE CENTER ALL REPAIRS DONE BY ANY ENTITY OTHER THAN AN AUTHORIZED ALESIS SERVICE CENTER SHALL BE SOLELY THE RESPONSIBILITY OF THAT ENTITY AND ALESIS SHALL HAVE NO LIABILITY TO THAT ENTITY OR TO ANY OTHER PARTY FOR ANY REPAIRS BY THAT ENTITY Regarding the Power Supply Fuse CAUTION The produc...

Страница 4: ...s stoves heat registers radiators or other heat producing equipment 7 Ventilation When installing the product make sure that the product has adequate ventilation Improperly ventilating the product may cause overheating which may damage the product 8 Mounting The product should only be used with a rack which the manufacturer recommends The combination of the product and rack should be moved careful...

Страница 5: ...ALESIS M1 Active MKII 8N SCHEMATIC AND PCB FILES ...

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ...8NPAB04a sch 1 Thu Nov 29 12 07 02 2001 ...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ...ALESIS M1 Active MKII 8N ECN HISTORY ...

Страница 19: ......

Страница 20: ...ALESIS M1 Active MKII 8N BOM ...

Страница 21: ...Q 6 5 NWCF w MAGNET 8 HOLE 8N 2 7 50 0144 EA STICKER BARCODE S N 8N 1 7 51 0092 EA MANUAL REFERENCE 8N 1 7 53 0018 EA STICKER QC W MFR DATE UL APPROVED 2 BACK PANEL 7 53 0160 EA LABEL LOGO 8N 2 CABINET 7 80 0276 EA BOX SHIPPING 8N 1 PACKOUT 7 80 0277 EA BOX GIFT 8N 1 PACKOUT 7 81 0147 EA FOAM SET TOP BOTTOM 1N 8N 1 7 90 0709 EA POLYBAG 7 x 9 2 MIL 1 LIT 7 90 1228 EA POLYBAG 12 x 14 x 28 2 MIL 2 CA...

Страница 22: ...R 129 x 25mm 8M 1 XLR 9 34 0016 EA FOAM GASKET POWER CONNECTOR 51 x 35mm 8M 1 IEC 9 34 0024 B EA FOAM MONOGASKET PORON 238 x 147mm 8M REV B 1 R P 9 96 0031 EA ASSY CABLE POWER SWITCH 8M 1 SWT P S 9 96 0032 EA ASSY CABLE 6 PIN 132mm 3 96mm PITCH 8M 1 P S AMP 9 96 0036 EA ASSY LED CABLE W LED 8M 1 AMP PCB 9 79 B601 EA ASSY PCB POWER SUPPLY 8M 1 10 00 CON Alesis Consigned Materi 20 00 VF Vendor Furni...

Страница 23: ... EA CAP 1000pF FILM 5 100V 1 C10 1 20 0224 EA CAP 0 22uF FILM 5 50V 1 C32 1 20 1684 EA CAP 0 68uF FILM 100V 15x9x18x18mm 1 C16 1 21 0104 EA CAP 0 1uF MONO 20 50V RADIAL 9 C11 C14 C25 29 C31 C33 1 22 2104 EA CAP 0 1uF CERDISC 10 100V X7R 2x 1x 15 1 C30 2 01 4007 EA DIODE POWER 1N4007 1000V 1A 4 D1 4 2 01 6220 EA DIODE POWER ULTRA FAST MUR860 600V 8A TO 220 4 D10 13 2 02 0600 EA DIODE POWER ULTRAFAS...

Страница 24: ...25 0x25 0 1 HS1 9 03 0068 EA HEATSINK 4 x TO 220 B6 REV A 1 HS2 9 40 B601 E EA PCB POWER SUPPLY 8M REV E 1 9 96 1386 EA ASSY PCB AMP JACK 8M 1 10 00 CON Alesis Consigned Materi 20 00 VF Vendor Furnished Materi 9 79 0195 EA ASSY PCB JACK 8M 1 10 00 CON Alesis Consigned Materi 20 00 VF Vendor Furnished Materi 0 09 0009 EA POT 10KA SINGLE 1 1 55 0470 EA CAP 47pF NPO 0805 50V 2 C26 27 4 05 0023 EA JAC...

Страница 25: ...50V 1 C11 1 20 0223 EA CAP 0 022uF FILM 5 100V 1 C37 1 20 0272 EA CAP 2700pF FILM 5 1 C38 1 20 0471 EA CAP 470pF FILM 5 50V 1 C10 1 55 0221 EA CAP 220pF NPO 0805 5 100V 2 C14 C45 1 55 0470 EA CAP 47pF NPO 0805 50V 3 C1 2 C48 1 56 0101 EA CAP 100pF NPO 0805 5 50V 4 C9 C13 C17 C47 1 56 0104 EA CAP 0 1uF X7R 0805 10 50V 20 C3 C8 C12 C16 C18 19 C29 30 C32 C35 C39 40 C44 C49 50 C52 55 C57 2 11 7815 EA ...