Alemlube 801A Скачать руководство пользователя страница 1

OWNER’S TECHNICAL MANUAL

301A Polypropylene Rotary Drum Pump

301A

Description

 The Alemlube 801A is a stainless steel manually operated rotary action drum pump specifically designed and engineered for the 

transfer of a wide range of chemicals and solvents contained in 205 litre or 60 litre drums. Heavy duty, durable, rugged and robust 

the 801A drum pump with its ryton rotor, 304 stainless steel inlet & outlet tubes and 304 stainless steel & teflon wetted parts 

provides excellent chemical compatibility. Capable of flow rates of up to 18L/min or 0.3L per rotation the 801A stainless steel rotary 

action drum pump from Alemlube offers years of dependable and trouble free service with periodical general maintenance. Ideal for 

all on demand fluid pumping requirements when reliability is paramount.

Specifications

Stainless Steel Rotary Action Drum Pump

801A

OWNER’S TECHNICAL MANUAL

Visit our website at  

www.alemlube.com.au

 or 

www.alemlube.co.nz

NSW
TEL: (02) 9939 0711
FAX: (02) 9939 0411

QLD/PNG
TEL: (07) 3204 9166
FAX: (07) 3204 1224

VIC/TAS
TEL: (03) 8787 8288
FAX: (03) 8787 8266

WA
TEL: (08) 9209 3066
FAX: (08) 9209 3933

SA/NT
TEL: (08) 8241 7111
FAX: (08) 8241 7011

NZ
TEL: (09) 447 1007
FAX: (09) 447 1008

1

Assembly and Installation

1     Contact your chemical or fluid supplier to check for compatibility with pump prior to 

installation and operation. 

2     Screw discharge spout into pump body outlet using Teflon tape provided or equivalent 

sealant tape. Do not use paste pipe sealant.

3     Slide handle over handle shaft and assemble to crank arm using the hex nut supplied. 

Attach entire crank arm subassembly, including handle, handle shaft, and hex nut, onto 

pump shaft taking care to align setscrew to indent in rotor shaft.

4     Thread suction tube into pump inlet. Thread suction tube into suction tube. Thread tail 

pipe onto suction tube section. Use Teflon tape provided or equivalent sealant tape to 

seal suction tube threaded connections. Do not use paste pipe sealant.

5     Thread bung adapter into drum.
6     Insert pump and suction tube assembly into bung adapter and hand-tighten bung 

adapter setscrew. Be sure to set pump and suction tube assembly so that the suction 

tube is at the desired depth in the barrel and is not blocked.

Operation

1     To begin pumping fluid, rotate handle clockwise several times making complete 

revolutions until fluid begins to flow. Several revolutions will be made with no fluid 

dispensed as pump needs to prime. Once primed, fluid flow begins as handle is 

rotated.

2     For siphoning or draining fluid back into barrel, place handle in the straight down 

position.

3     To stop siphoning and maintain suction or prime, leave handle in horizontal position.

Maintenance

Regularly check pump and suction tubes for leaks. Leaks in the suction line or in pump housing  
will cause inefficient pumping and loss of prime.

Uses:

low viscosity chemicals, lacquers, mild acids, herbicides, pesticides and mild detergents

Discharge Quantity:

Up to 18L/min or 0.3L rotation

Materials:

304 stainless steel inlet & outlet tubes and 304 stainless steel & teflon wetted parts

Delivery Rate:

up to 18L/min or 0.3L rotation

Suitable for use with:

60L and 205L drums

Working Temp:

140°F / 60°C

Mounting:

2” MNPT bung adapter

Max Viscosity:

5000 SSU

Содержание 801A

Страница 1: ...semble to crank arm using the hex nut supplied Attach entire crank arm subassembly including handle handle shaft and hex nut onto pump shaft taking care to align setscrew to indent in rotor shaft 4 Thread suction tube into pump inlet Thread suction tube into suction tube Thread tail pipe onto suction tube section Use Teflon tape provided or equivalent sealant tape to seal suction tube threaded con...

Страница 2: ... Gasoline is a highly flammable fuel The improper use handling or storage of gasoline can be dangerous Prevent accidents by following these safety rules a Use gasoline only as fuel never as a cleaning fluid b Use only an approved container to hold or store gasoline Never store gasoline in familiar containers such as milk containers or soda pop bottles c Store gasoline in a cool location out of the...

Страница 3: ...ed other than as stated in the LIMITED WARRANTY above is made or authorized by Dayton PRODUCT SUITABILITY Many jurisdictions have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary from those in neighbouring areas While Dayton attempts to assure that its products comply with such codes it cannot guarantee compliance and cannot...

Страница 4: ...PTFE 1 11 801A 11 Screws 304SS 8 12 801A 12 Crank Arm Aluminium 1 13 801A 13 Handle Nylon 1 14 801A 14 Handle rivet Steel 1 15 801A 15 Nut Steel 1 16 801A 16 Hexagon bolt Steel 1 17 801A 17 Adapter Screw Aluminum 304SS 1 18 801A 18 Thumb Screw Steel 304SS 1 19 801A 19 Suction tube 304SS 3 20 801A 20 Spout 304SS 1 4 Ordering Spare Parts Parts List Part No 801A NSW TEL 02 9939 0711 FAX 02 9939 0411 ...

Страница 5: ...p from side with suction discharge ports in vertical position and on right hand side Reposition rotor by grasping covers and sliding towards 3 o clock position Do not use excessive force Hold in position and retighten cover bolts 3 Suction line above liquid Suction line end must remain completely below fluid surface 4 Damaged worn pump parts Remove pump cover and inspect for broken or worn parts C...

Отзывы: