Alemlube 339000 Скачать руководство пользователя страница 3

Visit our website at  

www.alemlube.com.au

 or 

www.alemlube.co.nz

NSW/ACT
TEL: (02) 9677 1555
FAX: (02) 9675 1155

QLD/PNG
TEL: (07) 3204 9166
FAX: (07) 3204 1224

VIC/TAS
TEL: (03) 8787 8288
FAX: (03) 8787 8266

WA
TEL: (08) 9302 4199
FAX: (08) 9303 2095

SA/NT
TEL: (08) 8241 7111
FAX: (08) 8241 7011

NZ
TEL: (09) 447 1007
FAX: (09) 447 1008

3

Visit our website at  

www.alemlube.com.au

 or 

www.alemlube.co.nz

240V Diesel Transfer Pump

OWNER’S TECHNICAL MANUAL

339000

Usage Restrictions

Carefully read this manual before installation of the pump.
1.  Do not use the pump to draw in or pump liquids different from that mentioned in the paragraph “Usage field”
2.  Before starting the transfer, check if the diesel is going to be stored in an appropriate container.
3.  Pay attention not to direct the diesel to persons or things, to electric boards or electric components.
4.  Position the pump always in a way that the switch can’t be accidentally turned on.
5.  Turn off the power supply after every usage.
6.  Do not modify any part of the device in order not to compromise its functionality, the worker’s safety  

and the guarantee validity.

7.  In a case of components breaking, please be sure that the diesel would not be dispersed into the environment.
8.  Reparations with replacement of components must be done just with original spare parts.
9.  Because of safety reasons, the worker must check the pump each time it is used. Reparations and replacements 

must be done by our service centres. A direct intervention can be dangerous and void the guarantee.

WARNING:  

Turn off the power supply before any intervention on the device.  

If you have any doubts on its safety, please do not use it.

Power Supply

According to the model of the pump there is a power supply whose value can be found in the paragraph “Technical 

data”. Voltage may /- 5% its value, while the frequency may /- 2%. In each pump there is a start/stop 

push-button, which is on the top of the electric engine within a rugged enclosure. 
Pos. 0 = Off position (opened circuit): the pump is deactivated.
Pos. 1 = On position (closed circuit).
If the pump stops working during use, turn off the power supply before any intervention.

WARNING:  

The power supply with values different from those indicated, may cause damage to the pump.

Choice and Connection of Feeder

1.  Use feeders with minimum section 3 x 1 mm

2

2.  Use high quality feeders like H 05 – VVF type or similar.
3.  Do not damage the feeder passing over it with machines or equipment.
4.  Do not position the feeder over damp surfaces or wet land.
The feeder integrity must be always checked before every usage of the pump.  

If there are abrasions or damages, please ask for authorised staff intervention.

WARNING:  

The feeder can only be changed by Alemlube or by authorised staff.

Содержание 339000

Страница 1: ...l Prior to installation carefully check the contents of the packaging and thoroughly read this documentation Installation and pump operation must be in accordance with the safety and workplace laws of your country The pump must be correctly installed with regard to all personal safety rules and to avoid damages which may void your right to the Alemlube two year warranty PRODUCT SPECIFICATIONS Flow...

Страница 2: ... footing and balance at all times to prevent tripping falling back injury etc 6 DO NOT use the equipment when tired or under the influence of drugs alcohol or medication A moment of inattention while operating this equipment may result in serious personal injury 1 Read the following precautions and instructions before you begin assembly or using 2 Failure to comply with these instructions could re...

Страница 3: ... just with original spare parts 9 Because of safety reasons the worker must check the pump each time it is used Reparations and replacements must be done by our service centres A direct intervention can be dangerous and void the guarantee WARNING Turn off the power supply before any intervention on the device If you have any doubts on its safety please do not use it Power Supply According to the m...

Страница 4: ...essure loss during the suction elbow and contraction of the tubes using a non minimum diameter tube and maintaining a clean suction filter Never work the pump dry without diesel inside the body of the pump The diesel pump can be installed both in vertical and horizontal positions taking care to fix it on the support plane with bolts suitable for the fixing holes present on the base of the electric...

Страница 5: ...filter is obstructed The foot valve is obstructed The suction tube is obstructed Suction too high Presence of air during the suction Working in by pass The by pass valve is locked The suction tube narrows The rotor is obstructed Clean the filter Clean or replace the valve Clean or replace the suction tube Draw up the pump to the diesel static level Check the connections tightness Reduce the charge...

Страница 6: ... 09 447 1008 6 Ordering Spare Parts Parts List Part No 339000 339000 22 339000 23 339000 24 339000 13 339000 12 339000 4 339000 10 339000 11 339000 9 339000 8 339000 7 339000 6 339000 4 339000 5 339000 1 339000 2 339000 3 339000 4 339000 12 339000 13 339000 14 339000 15 339000 16 339000 38 339000 34 339000 33 339000 35 339000 31 339000 37 339000 34 339000 36 339000 30 339000 29 339000 28 339000 25...

Страница 7: ...11 Anti Vibration Plug 1 339000 12 Flange 2 339000 13 O Ring 2 339000 14 Screw M8x100 1 339000 15 Washer 1 339000 16 By Pass 1 339000 17 Network Filter 1 339000 18 Filter Support Spring 1 339000 19 O Ring 1 339000 20 Filter Cap 1 Ordering Spare Parts Parts List Part No 339000 Part Number Description Qty 339000 21 White Filter Adhesive 1 339000 22 By Pass Spring 1 339000 23 Washer 1 339000 24 Self ...

Отзывы: